What advantage is there to be gained using large modular metal-on-metal bearings in routine primary hip replacement? A preliminary report of a prospective randomised controlled trial.

نویسندگان

  • A Malviya
  • J R Ramaskandhan
  • R Bowman
  • M Hashmi
  • J P Holland
  • S Kometa
  • E Lingard
چکیده

The aim of this study was to investigate the possible benefit of large-head metal-on-metal bearing on a stem for primary hip replacement compared with a 28 mm diameter conventional metal-on-polyethylene bearing in a prospective randomised controlled trial. We investigated cemented stem behaviour between these two different bearings using Einzel-Bild-Röntgen-Analyse, clinical and patient reported measures (Harris hip score, Western Ontario and McMaster Universities osteoarthritis index, Short Form-36 and satisfaction) and whole blood metal ion levels at two years. A power study indicated that 50 hips were needed in each group to detect subsidence of > 5 mm at two years with a p-value of < 0.05. Significant improvement (p < 0.001) was found in the mean clinical and patient reported outcomes at two years for both groups. Comparison of outcomes between the groups at two years showed no statistically significant difference for mean stem migration, clinical and patient reported outcomes; except overall patient satisfaction which was higher for metal-on-metal group (p = 0.05). Metal ion levels were raised above the Medicines and Healthcare products Regulatory Agency advised safety level (7 µg per litre) in 20% of the metal-on-metal group and in one patient in metal-on-polyethylene group (who had a metal-on-metal implant on the contralateral side). Two patients in the metal-on-metal group were revised, one for pseudotumour and one for peri-prosthetic fracture. Use of large modular heads is associated with a risk of raised whole blood metal ion levels despite using a proven bearing from resurfacing. The head-neck junction or excess stem micromotion are possibly the weak links warranting further research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.

We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Meta...

متن کامل

A prospective randomized clinical trial comparing metal-on-metal total hip arthroplasty and metal-on-metal total hip resurfacing in patients less than 65 years old.

The purpose of this prospective randomised study is to compare the early clinical results of the metal-on-metal hip resurfacing to metal-on-metal THA. Two hundred and ten hips were randomised between August 2003 and January 2006 (191 subjects). One hundred and two hips were implanted with an uncemented titanium tapered stem, and an uncemented titanium acetabular component and 28 mm metal-on-met...

متن کامل

Increased Mortality in Metal-on-Metal versus Non-Metal-on-Metal Primary Total Hip Arthroplasty at 10 Years and Longer Follow-Up: A Systematic Review and Meta-Analysis

IMPORTANCE There are concerns about increased mortality in patients with metal-on-metal bearings in total hip arthroplasty (THA). OBJECTIVE To determine the mortality and the morbidity in patients with metal-on-metal articulations (MOM THA) compared to patients with non-metal-on-metal articulations (non-MOM THA) after primary total hip arthroplasty. DATA SOURCES Search of PubMed, MEDLINE, E...

متن کامل

Taper junction failure in large-diameter metal-on-metal bearings

OBJECTIVES An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer. METHODS Analysis was carried out using highly accurate coordinate measuring to calculate volumetric and linear rates of the articular...

متن کامل

Consensus statement "Current evidence on the management of metal-on-metal bearings"--April 16, 2012.

a. What are the benefits (effectiveness)? MoM is currently the only technique for surface replacement. There are no polyethylene particles in pure MoM bearings that may cause osteolysis. MoM bearings produce less volumetric wear compared to conventional polyethylene. There is a reduced risk of fracture in MoM bearings compared to ceramics. Large head Total Hip Replacement (THR) (36mm head size ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 12  شماره 

صفحات  -

تاریخ انتشار 2011