Composite resin microhardness: the influence of light curing method, composite shade, and depth of cure.

نویسندگان

  • Camila Silveira de Araújo
  • Marcelo Thome Schein
  • Cesar Henrique Zanchi
  • Sinval Adalberto Rodrigues
  • Flavio Fernando Demarco
چکیده

AIM The aim of this study was to investigate the influence of light curing method, composite shade, and depth of cure on composite microhardness. METHODS AND MATERIALS Forty-eight specimens with 4 mm of depth were prepared with a hybrid composite (Filtek Z-100, 3M ESPE); 24 with shade A1 and the remaining with shade C2. For each shade, two light curing units (LCUs) were used: a quartz-tungsten-halogen (QTH) LCU (Optilight Plus - Gnatus) and a light emitting diode (LED) LCU (LEC 470 II - MM Optics). The LED LCU was tested using two exposure times (LED 40 seconds and LED 60 seconds). After 24-hour storage, three indentations were made at mm depth intervals using a Knoop indenter. Data were submitted to three-way analysis of variance (ANOVA) and Tukey's test (p<0.05). RESULTS The three factors tested (light curing method, shade, and depth) had a significant influence on the composite microhardness (p<0.05). All groups presented similar hardness values in the first mm, except for composite shade C2 cured with LED for 40 seconds. The hardness decreased with depth, especially for shade C2 for 40 seconds. Increasing light-curing time with LED produced hardness values similar to the QTH. CONCLUSIONS The light curing method including variations of time, the depth of cure, and the composite shade influence the composite microhardness. CLINICAL SIGNIFICANCE Clinicians should avoid thicker increments when working with composite restorations. Extended light-curing time might be indicated depending on the composite shade and on the light-curing device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the Distance of the Curing Light Source and Composite Shade on Hardness of Two Composites

This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The spe...

متن کامل

Composite Depth of Cure Using Four Polymerization Techniques

UNLABELLED The light-curing technique is relevant to reduce the degree of polymerization shrinkage, improving clinical and esthetic success of composite resin restorations. OBJECTIVE To evaluate in vitro the effect of four light-curing techniques on depth of cure of a composite resin. MATERIAL AND METHODS Ten specimens of a composite resin were made in cylindrical cavities prepared in PVC p...

متن کامل

Curing effectiveness of resin composites at different exposure times using LED and halogen units.

OBJECTIVE To compare the polymerization effectiveness of two resin composites cured with a quartz tungsten halogen (QTH) lamp or a light emitting diodes (LED) unit. STUDY DESIGN Filtek Z250 (3M ESPE) and Spectrum TPH (Dentsply DeTrey) resin composites were placed in 9 mm deep and 4 mm wide metallic molds and cured using the QTH light Hilux 200 (Benlioglu) or the LED unit Smartlite IQ (Dentspl...

متن کامل

Effect of composite shade, curing time and mode on temperature rise of silorane and methacrylate- based composite resins

Introduction: The present study was performed to evaluate the effects of light-curing modes and shades of methacrylate and silorane-based composite resins on temperature rise during polymerization of composite resins. Materials &Methods: In this in vitro study, ninety composite samples with two types of composite resin - methacrylate-based and a low-shrinkage silorane-based were prepared, in...

متن کامل

Influence of Light Curing Source on Microhardness of Composite Resins of Different Shades

INTRODUCTION The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. PURPOSE This study evaluated the microhardne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2008