Assessing the Methodology for Calculating Platelet Contribution to Clot Strength (Platelet Component) in Thromboelastometry and Thrombelastography

نویسندگان

  • Cristina Solomon
  • Marco Ranucci
  • Gerald Hochleitner
  • Herbert Schöchl
  • Christoph J. Schlimp
چکیده

The viscoelastic properties of blood clot have been studied most commonly using thrombelastography (TEG) and thromboelastometry (ROTEM). ROTEM-based bleeding treatment algorithms recommend administering platelets to patients with low EXTEM clot strength (e.g., clot amplitude at 10 minutes [A10] <40 mm) once clot strength of the ROTEM® fibrin-based test (FIBTEM) is corrected. Algorithms based on TEG typically use a low value of maximum amplitude (e.g., <50 mm) as a trigger for administering platelets. However, this parameter reflects the contributions of various blood components to the clot, including platelets and fibrin/fibrinogen. The platelet component of clot strength may provide a more sensitive indication of platelet deficiency than clot amplitude from a whole blood TEG or ROTEM® assay. The platelet component of the formed clot is derived from the results of TEG/ROTEM® tests performed with and without platelet inhibition. In this article, we review the basis for why this calculation should be based on clot elasticity (e.g., the E parameter with TEG and the CE parameter with ROTEM®) as opposed to clot amplitude (e.g., the A parameter with TEG or ROTEM®). This is because clot elasticity, unlike clot amplitude, reflects the force with which the blood clot resists rotation within the device, and the relationship between clot amplitude (variable X) and clot elasticity (variable Y) is nonlinear. A specific increment of X (ΔX) will be associated with different increments of Y (ΔY), depending on the initial value of X. When calculated correctly, using clot elasticity data, the platelet component of the clot can provide a valuable insight into platelet deficiency in emergency bleeding.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revisiting Hartert’s 1962 Calculation of the Physical Constants of Thrombelastography

Thrombelastography (TEG)/thromboelastometry (ROTEM) devices measure viscoelastic clot strength as clot amplitude (A). Transformation of clot amplitude into clot elasticity (E with TEG; CE with ROTEM) is sometimes necessary (eg, when calculating platelet component of the clot). With TEG, clot amplitude is commonly transformed into shear modulus (G; expressed in Pa or dyn/cm2) as follows: G = (50...

متن کامل

Assessing platelet and fibrinogen contribution to clot strength using modified thromboelastography in pregnant women.

UNLABELLED The monoclonal antibody fragment c7E3 Fab (ReoPro), by binding to platelet surface fibrinogen receptors (glycoprotein, GPIIb/IIIa), inhibits platelet aggregation and its interaction with fibrinogen. In this study, we used thromboelastography with ReoPro to evaluate the independent contribution of fibrinogen and platelets to clot strength. Thromboelastography was performed in 21 healt...

متن کامل

Rotational thromboelastometry predicts thromboembolic complications after major non-cardiac surgery

INTRODUCTION Thromboembolic complications contribute substantially to perioperative morbidity and mortality. Routine laboratory tests do not detect patients with acquired or congenital hypercoagulability who may be at increased risk of perioperative thromboembolism. Rotational thromboelastometry (ROTEM) is a digitized modification of conventional thromboelastography that is stable and technical...

متن کامل

Fibrin Clot Strength in Patients with Diabetes Mellitus Measured by Thrombelastography

Background Patients with diabetes mellitus (DM) exhibit increased risk of recurrent myocardial infarction. Maximal clot strength measured by thrombelastography (TEG) is a risk factor for recurrent ischemic events. We hypothesized that diabetic subjects exhibit increased fibrin clot strength in platelet-poor plasma and that glycemic control correlates with maximal fibrin clot strength. Methods...

متن کامل

Correlation of conventional thrombelastography and rapid thrombelastography in trauma.

BACKGROUND Conventional thrombelastography has been in use for over 6 decades and provides a functional assay of coagulation. Rapid thrombelastography was developed to provide more rapid comprehensive analysis of coagulation status in an emergency setting. The purpose of this study was to determine the correlation of rapid thrombelastographic values with conventional thrombelastographic values ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 121  شماره 

صفحات  -

تاریخ انتشار 2015