Reference-free quantification of EEG spectra: combining current source density (CSD) and frequency principal components analysis (fPCA).

نویسندگان

  • Craig E Tenke
  • Jürgen Kayser
چکیده

OBJECTIVE Definition of appropriate frequency bands and choice of recording reference limit the interpretability of quantitative EEG, which may be further compromised by distorted topographies or inverted hemispheric asymmetries when employing conventional (non-linear) power spectra. In contrast, fPCA factors conform to the spectral structure of empirical data, and a surface Laplacian (2-dimensional CSD) simplifies topographies by minimizing volume-conducted activity. Conciseness and interpretability of EEG and CSD fPCA solutions were compared for three common scaling methods. METHODS Resting EEG and CSD (30 channels, nose reference, eyes open/closed) from 51 healthy and 93 clinically-depressed adults were simplified as power, log power, and amplitude spectra, and summarized using unrestricted, Varimax-rotated, covariance-based fPCA. RESULTS Multiple alpha factors were separable from artifact and reproducible across subgroups. Power spectra produced numerous, sharply-defined factors emphasizing low frequencies. Log power spectra produced fewer, broader factors emphasizing high frequencies. Solutions for amplitude spectra showed optimal intermediate tuning, particularly when derived from CSD rather than EEG spectra. These solutions were topographically distinct, detecting multiple posterior alpha generators but excluding the dorsal surface of the frontal lobes. Instead a low alpha/theta factor showed a secondary topography along the frontal midline. CONCLUSIONS CSD amplitude spectrum fPCA solutions provide simpler, reference-independent measures that more directly reflect neuronal activity. SIGNIFICANCE A new quantitative EEG approach affording spectral components is developed that closely parallels the concept of an ERP component in the temporal domain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current source density measures of electroencephalographic alpha predict antidepressant treatment response.

BACKGROUND Despite recent success in pharmacologic treatment of depression, the inability to predict individual treatment response remains a liability. This study replicates and extends findings relating pretreatment electroencephalographic (EEG) alpha to treatment outcomes for serotonergic medications. METHODS Resting EEG (eyes-open and eyes-closed) was recorded from a 67-electrode montage i...

متن کامل

Novelty P3 reductions in depression: characterization using principal components analysis (PCA) of current source density (CSD) waveforms.

We previously reported a novelty P3 reduction in depressed patients compared to healthy controls (n=20 per group) in a novelty oddball task using a 31-channel montage. In an independent replication and extension using a 67-channel montage (n=49 per group), reference-free current source density (CSD) waveforms were simplified and quantified by a temporal, covariance-based principal components an...

متن کامل

Posterior EEG alpha at rest and during task performance: Comparison of current source density and field potential measures.

Resting and task-related EEG alpha are used in studies of cognition and psychopathology. Although Laplacian methods have been applied, apprehensions about loss of global activity dissuade researchers from greater use except as a supplement to reference-dependent measures. The unfortunate result has been continued reliance on reference strategies that differ across labs, and a systemic preferenc...

متن کامل

Comparison of data transformation procedures to enhance topographical accuracy in time-series analysis of the human EEG.

We describe a methodology to apply current source density (CSD) and minimum norm (MN) estimation as pre-processing tools for time-series analysis of single trial EEG data. The performance of these methods is compared for the case of wavelet time-frequency analysis of simulated gamma-band activity. A reasonable comparison of CSD and MN on the single trial level requires regularization such that ...

متن کامل

Principal components analysis of Laplacian waveforms as a generic method for identifying ERP generator patterns: I. Evaluation with auditory oddball tasks.

OBJECTIVE To evaluate the effectiveness and comparability of PCA-based simplifications of ERP waveforms versus their reference-free Laplacian transformations for separating task- and response-related ERP generator patterns during auditory oddball tasks. METHODS Nose-referenced ERPs (31 sites total) were recorded from 66 right-handed adults during oddball tasks using syllables or tones. Respon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 116 12  شماره 

صفحات  -

تاریخ انتشار 2005