Multicenter comparison of ESP Culture System II with BACTEC 460TB and with Lowenstein-Jensen medium for recovery of mycobacteria from different clinical specimens, including blood.

نویسندگان

  • E Tortoli
  • P Cichero
  • M G Chirillo
  • M R Gismondo
  • L Bono
  • G Gesu
  • M T Simonetti
  • G Volpe
  • G Nardi
  • P Marone
چکیده

The recently developed ESP Culture System II (AccuMed, Chicago, Ill.) was compared with radiometric BACTEC 460TB (Becton Dickinson, Towson, Md.) and with Lowenstein-Jensen medium for recovery of mycobacteria from over 2,500 clinical specimens both of respiratory and nonrespiratory origin, including blood. The majority of the 219 mycobacterial isolates (129) belonged to the Mycobacterium tuberculosis complex, followed by 37 isolates of the Mycobacterium avium complex (MAC) and 53 isolates of eight other mycobacterial species. Rates of recovery obtained with BACTEC, ESP, and Lowenstein-Jensen medium were 89, 79, and 64%, respectively, with such differences being statistically significant. Different media and systems appeared to behave differently when the more frequently detected organisms were considered: M. tuberculosis complex isolates grew better with BACTEC, and MAC isolates grew better with ESP. An analysis of the combinations of Lowenstein-Jensen medium with BACTEC and with ESP did not reveal significant differences in recovery rates. With regard to the times needed for the detection of positive cultures, they were significantly longer on Lowenstein-Jensen medium (average, 28 days) than with the remaining two systems, between which there was no difference (average, 18 days). We conclude, therefore, that the ESP system, when used in combination with a solid medium, performs as well as the thoroughly validated radiometric BACTEC system and offers the advantages of full automation and absence of radioisotopes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the BACTEC MGIT 960 and BACTEC 460TB systems for detection of mycobacteria in clinical specimens.

The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid detection of mycobacteria in clinical specimens was evaluated and compared to the radiometric method (BACTEC 460TB) and to mycobacterial culture on Lowenstein-Jensen (LJ) medium. Clinical specimens (n = 590) were tested without selection. A total of 121 (20.5%) isolates of mycobacteria were recovered; 98 (81.0...

متن کامل

Comparative evaluation of BACTEC 460TB system and Lowenstein-Jensen medium for the isolation of M. tuberculosis from cerebrospinal fluid samples of tuberculous meningitis patients.

PURPOSE To evaluate the role of the radiometric BACTEC 460TB system and the conventional Lowenstein-Jensen (LJ) medium for isolation of M. tuberculosis from cerebrospinal fluid (CSF) samples of tuberculous meningitis (TBM) patients. METHODS CSF specimens (n=2325) from suspected TBM patients were processed for isolation of mycobacteria by inoculating BACTEC 12B medium and the LJ medium. The is...

متن کامل

Evaluation of BACTEC MGIT 960 and BACTEC 460TB systems for recovery of mycobacteria from clinical specimens of a university hospital with low incidence of tuberculosis.

Clinical samples obtained over a period of 8 months (n = 2,624) were processed in parallel with the BACTEC 460TB system, with the MGIT 960 system, and in Löwenstein-Jensen (LJ) medium, resulting in the recovery of 127 mycobacteria. Recovery rates in combinations of the BACTEC 460TB or MGIT 960 system with LJ were, respectively, 94.7 and 94.7% for Mycobacterium tuberculosis complex (n = 57) and ...

متن کامل

Use of BACTEC MGIT 960 for recovery of mycobacteria from clinical specimens: multicenter study.

The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automa...

متن کامل

Comparison of the MB/BacT and BACTEC 460 TB systems for recovery of mycobacteria from various clinical specimens.

A total of 1,830 specimens (75.7% respiratory and 24.3% nonrespiratory) were cultured in parallel with the MB/BacT and BACTEC 460 TB systems and on Lowenstein-Jensen (LJ) medium. Mycobacteria were identified from 173 (6.5%) specimens. The most common species recovered were Mycobacterium tuberculosis complex (65. 9%), Mycobacterium avium complex (22.5%), and Mycobacterium chelonae (9.2%). The re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 1998