Percutaneous left ventricular assist devices in ventricular tachycardia ablation: multicenter experience.
نویسندگان
چکیده
BACKGROUND Data on relative safety, efficacy, and role of different percutaneous left ventricular assist devices for hemodynamic support during the ventricular tachycardia (VT) ablation procedure are limited. METHODS AND RESULTS We performed a multicenter, observational study from a prospective registry including all consecutive patients (N=66) undergoing VT ablation with a percutaneous left ventricular assist devices in 6 centers in the United States. Patients with intra-aortic balloon pump (IABP group; N=22) were compared with patients with either an Impella or a TandemHeart device (non-IABP group; N=44). There were no significant differences in the baseline characteristics between both the groups. In non-IABP group (1) more patients could undergo entrainment/activation mapping (82% versus 59%; P=0.046), (2) more number of unstable VTs could be mapped and ablated per patient (1.05±0.78 versus 0.32±0.48; P<0.001), (3) more number of VTs could be terminated by ablation (1.59±1.0 versus 0.91±0.81; P=0.007), and (4) fewer VTs were terminated with rescue shocks (1.9±2.2 versus 3.0±1.5; P=0.049) when compared with IABP group. Complications of the procedure trended to be more in the non-IABP group when compared with those in the IABP group (32% versus 14%; P=0.143). Intermediate term outcomes (mortality and VT recurrence) during 12±5-month follow-up were not different between both groups. Left ventricular ejection fraction ≤15% was a strong and independent predictor of in-hospital mortality (53% versus 4%; P<0.001). CONCLUSIONS Impella and TandemHeart use in VT ablation facilitates extensive activation mapping of several unstable VTs and requires fewer rescue shocks during the procedure when compared with using IABP.
منابع مشابه
Outcomes of Ventricular Tachycardia Ablation Using Percutaneous Left Ventricular Assist Devices.
BACKGROUND Although percutaneous left ventricular assist devices (pLVADs) facilitate mapping and ablation of hemodynamically unstable ventricular tachycardia (VT), there is limited data whether clinical outcomes are improved. We sought to retrospectively compare the outcomes of patients undergoing scar-related VT ablation with and without pLVAD support. METHODS AND RESULTS The study populatio...
متن کاملThe role of percutaneous left ventricular assist devices during ventricular tachycardia ablation.
Ventricular tachycardia (VT) is a common but serious arrhythmia that significantly adds to the morbidity and mortality of patients with structural heart disease. Percutaneous catheter ablation has evolved to be standard therapy to prevent recurrent implantable cardioverter defibrillator shocks from VT in patients on antiarrhythmia medications. Procedural outcomes in patients with structural hea...
متن کاملSuccessful catheter ablation of hemodynamically significant ventricular tachycardia in a patient with biventricular assist device support
Introduction Ventricular assist devices (VADs) are playing a large role in the management of end-stage heart failure. Approximately 35% of patients with a VAD have ventricular arrhythmias within the first month of implantation. Electrophysiologic ablations in the setting of a VAD are limited to left VADs (LVADs). To our knowledge, we describe the first report of ablation of a hemodynamically si...
متن کاملCombined use of TandemHeart percutaneous ventricular assist device and Stereotaxis magnetic navigation during cardiac ablation procedure
Ventricular tachycardia (VT) is common in patients with advanced heart failure, and medical therapy alone may have limited success. Implantable cardioverter defibrillators (ICDs) have been widely accepted as standard of care for VT management and prevention of sudden cardiac death. However, this therapy does not in itself reduce episodes of clinical VT. For patients who do not respond well to m...
متن کاملWhen Ablation Is Not the Answer: Acute Left Main Thrombosis Causing Incessant Ventricular Tachycardia Following Left Ventricular Assist Device Implant
Ventricular arrhythmia from aortic cusp thrombosis and coronary embolization is a rare complication of left ventricular assist device (LVAD) implantation. In this report, we present a case of acute left main and left anterior descending artery occlusion from embolic aortic cusp thrombi after LVAD implant. The patient presented with chest pain and incessant ventricular tachycardia post-LVAD impl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2014