New trends in intraocular lens imaging [8011-324]

نویسندگان

  • María S. Millán
  • Francisco Alba-Bueno
  • Fidel Vega
چکیده

As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the eye in near vision. Finally, we present a theoretical approach that considers the modification of less conventional ocular parameters to compensate for possible refractive errors after the IOL implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acuity and Depth of Focus with spherical and aspheric Intraocular Lenses

References [1] Díaz-Uribe, R. and Campos-García, M., “Null-screen testing of fast convex aspheric surfaces,” Appl Opt, 39, 2670–2677 (2000). [2] D. Malacara-Doblado and I. Ghozeil, “Hartmann and other screen tests”, in [Optical Shop Testing], Third Ed., D. Malacara, ed. (Wiley, 2007), 361-394. [3] Moreno-Oliva, V. I., Campos-García, M., Bolado-Gómez, R. and Díaz-Uribe, R., “Point shifting in th...

متن کامل

Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation

The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

Management of absent capsular support with a new Intraocular Lens design

Purpose: To describe a new intraocular lens that can be implanted in case of rupture of the posterior capsule and lack of capsular support. Methods: This experimental study was carried out on ten Flanders rabbits. The right eye of each rabbit underwent intra capsular lens extraction and two peripheral iridectomies, and the new lens was implanted with an optic rest in the posterior chamber. Addi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011