Title: the Photometric Accuracy of the Foc

نویسنده

  • Gerhardt R. Meurer
چکیده

A comparison is made between the expected photometric accuracy of the FOC, and that observed. The presently known systematic eeects are listed and quantiied. Typically when both internal and external factors are included one only expects to obtain photometry accurate to 0.2 mag in the ultraviolet. This expectation is tested by comparing magnitudes extracted from F220W images of nine starburst galaxies with those extracted from IUE spectra. After removing one discrepant observation, it is found that relative to the IUE, the FOC external errors are 0:05 mag, three times lower than expected. By carefully removing some of the internal zeropoint variations, one should be able to reduce the total systematic errors to 0:10 mag.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of SLIM Dynamic Models Based on Vector Control for Railway Applications

Although, Single-Sided Linear Induction Motor (SLIM) utilization has increased in railway applications due to their numerous advantages in comparison to Rotational Induction Motors (RIM), there are some sophistication in their mathematical models and electrical drive. This paper focuses on the problems of SLIM modeling, with assuming end-effect on the basis of Field Oriented Control (FOC) as a ...

متن کامل

Effect of a Childbirth Psychoeducation Program on the Level of Fear of Childbirth in Primigravid Women

Background: Severe fear of childbirth (FOC) is the most important cause of elective and emergency cesarean section and results in an unpleasant experience among women. Implementing a psychoeducational program can promote mothers’ knowledge and reduce the FOC. Aim: the aim of this study was to determine the effect of childbirth psychoeducational program on the FOC intensity in primigravid women....

متن کامل

Improvement Performances of Active and Reactive Power Control Applied to DFIG for Variable Speed Wind Turbine Using Sliding Mode Control and FOC

This paper deals with the Active and Reactive Power control of double-fed induction generator (DFIG) for variable speed wind turbine. For controlling separately the active and the reactive power generated by a DFIG, field oriented control (FOC) and indirect sliding mode control (ISMC) are presented. These non linear controls are compared on the basis of topology, cost, efficiency. The main cont...

متن کامل

Improve dynamic performance of fixed speed wind turbines using unified power flow controller (UPFC) and fractional order controller (FOC)

Wind powers are very unstable in voltage fluctuations, especially in short circuit error and sharp and sudden voltage drops, which one of its main reasons is the use of induction generators in these power plants and thus need to reactive power and high magnetizing current. To improve the ride_through voltage from WECS in error conditions and damping the oscillations of the induction generator r...

متن کامل

Definitions, measurements and prevalence of fear of childbirth: a systematic review

BACKGROUND Fear of Childbirth (FOC) is a common problem affecting women's health and wellbeing, and a common reason for requesting caesarean section. The aims of this review were to summarise published research on prevalence of FOC in childbearing women and how it is defined and measured during pregnancy and postpartum, and to search for useful measures of FOC, for research as well as for clini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007