Simplified Minimum Copper Loss Remedial Control of a Five-Phase Fault-Tolerant Permanent-Magnet Vernier Machine under Short-Circuit Fault

نویسندگان

  • Chenyu Gu
  • Wenxiang Zhao
  • Bufeng Zhang
  • Paolo Mercorelli
چکیده

Abstract: A fault-tolerant permanent-magnet vernier (FT-PMV) machine incorporates the merits of high fault-tolerant capability and high torque density. In this paper, a new remedial control is proposed for a five-phase FT-PMV machine with short-circuit fault of stator windings. Based on the principle of copper loss minimization, the aims of the proposed control strategy are to keep magnetic motive force (MMF) unchanged and minimize torque ripple. The proposed remedial control strategy contains two parts. Firstly, the remedial currents of the healthy phases are used to compensate for the ripple of MMF caused by the short-circuit current. Secondly, an open-circuit fault-tolerant control strategy is used to compensate for the lack of normal torque in the fault phase. Finally, the vector sum of two parts is adopted to derive the remedial currents. The final expression of the proposed remedial current is simpler than that than these previous methods. In addition, the proposed remedial currents are sinusoidal, which can reduce the reactive component in instantaneous power produced by pulsating torque and iron loss of a sine back-EMF machine. A FT-PMV prototype is built. The simulations and the experiments verify the effectiveness of the proposed strategy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Neutral Point Current Control on Copper Loss Distribution of Five Phase PM Generators Used in Wind Power Plants

Efficiency improvement under faulty conditions is one of the main objectives of fault tolerant PM drives. This goal can be achieved by increasing the output power while reducing the losses. Stator copper loss not only directly affects the total efficiency, but also plays an important role in thermal stress generations of iron core. In this paper, the effect of having control on neutral point cu...

متن کامل

Torque-Ripple Minimization in Modular Permanent-Magnet Brushless Machines

This paper discusses the suitability of four-phase, five-phase, and six-phase modular machines, for use in applications where servo characteristics and fault tolerance are key requirements. It is shown that an optimum slot number and pole number combination exists, for which excellent servo characteristics could be achieved, under healthy operating conditions, with minimum effects on the power ...

متن کامل

Harmonic Analysis and Fault-Tolerant Capability of a Semi-12-Phase Permanent-Magnet Synchronous Machine Used for EVs

This paper deals with a fault-tolerant semi-12-phase permanent-magnet synchronous machine (PMSM) used for electric vehicles. High fault-tolerant and low toque ripple features are achieved by employing fractional slot concentrated windings (FSCWs) and open windings. Excessive magnetomotive force (MMF) harmonic components can lead to thermal demagnetization of rotor magnets as well as high core l...

متن کامل

Design and Analysis of Linear Fault-Tolerant Permanent-Magnet Vernier Machines

This paper proposes a new linear fault-tolerant permanent-magnet (PM) vernier (LFTPMV) machine, which can offer high thrust by using the magnetic gear effect. Both PMs and windings of the proposed machine are on short mover, while the long stator is only manufactured from iron. Hence, the proposed machine is very suitable for long stroke system applications. The key of this machine is that the ...

متن کامل

Design of an Active Approach for Detection, Estimation and Short-Circuit Stator Fault Tolerant Control in Induction Motors

Three phase induction motors have many applications in industries. Consequently, detecting and estimating the fault and compensate it in a way that the faulty induction motor satisfies the predefined goals are important issues. One of the most common faults in induction motors is the short circuit of the stator winding. In this paper, an active fault-tolerant control system is designed and pres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016