Volumetric‐modulated arc therapy using multicriteria optimization for body and extremity sarcoma
نویسندگان
چکیده
This study evaluates the implementation of volumetric-modulated arc therapy (VMAT) using multicriteria optimization (MCO) in the RayStation treatment planning system (TPS) for complex sites, namely extremity and body sarcoma. The VMAT-MCO algorithm implemented in RayStation is newly developed and requires an integrated, comprehensive analysis of plan generation, delivery, and treatment efficiency. Ten patients previously treated by intensity-modulated radiation therapy (IMRT) with MCO were randomly selected and replanned using VMAT-MCO. The plan quality was compared using homogeneity index (HI) and conformity index (CI) of the planning target volume (PTV) and dose sparing of organs at risk (OARs). Given the diversity of the tumor location, the 10 plans did not have a common OAR except for skin. The skin D50 and Dmean was directly compared between VMAT-MCO and IMRT-MCO. Additional OAR dose points were compared on a plan-by-plan basis. The treatment efficiency was compared using plan monitor units (MU) and net beam-on time. Plan quality assurance was performed using the Sun Nuclear ArcCHECK phantom and a gamma criteria of 3%/3 mm. No statistically significant differences were found between VMAT- and IMRT-MCO for HI and CI of the PTV or D50 and Dmean to the skin. The VMAT-MCO plans showed general improvements in sparing to OARs. The VMAT-MCO plan set showed statistically significant improvements over the IMRT-MCO set in treatment efficiency per plan MU (p < 0.05) and net beam-on time (p < 0.01). The VMAT-MCO plan deliverability was validated. Similar gamma passing rates were observed for the two modalities. This study verifies the suitability of VMAT-MCO for sarcoma cancer and highlighted the comparability in plan quality and improve-ment in treatment efficiency offered by VMAT-MCO as compared to IMRT-MCO.
منابع مشابه
Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملMulticriteria optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction.
PURPOSE To develop a method for inverse volumetric-modulated arc therapy (VMAT) planning that combines multicriteria optimization (MCO) with direct machine parameter optimization. The ultimate goal is to provide an efficient and intuitive method for generating high quality VMAT plans. METHODS Multicriteria radiation therapy treatment planning amounts to approximating the relevant treatment op...
متن کاملMulticriteria VMAT optimization.
PURPOSE To make the planning of volumetric modulated arc therapy (VMAT) faster and to explore the tradeoffs between planning objectives and delivery efficiency. METHODS A convex multicriteria dose optimization problem is solved for an angular grid of 180 equi-spaced beams. This allows the planner to navigate the ideal dose distribution Pareto surface and select a plan of desired target covera...
متن کاملDosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma
Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...
متن کامل