Shaping ability of reciprocating single-file and full-sequence rotary instrumentation systems in simulated curved canals
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to evaluate the shaping ability of three nickel-titanium systems in simulated curved canals. MATERIALS AND METHODS Sixty simulated canals were prepared to apical size 25 with Reciproc, S5, and twisted file (TF) instruments. Standardized pre and postoperative images were taken using a digital camera, were superimposed and aberrations were recorded. Material removal was measured at five points: The canal orifice, halfway to the orifice, beginning of the curve, the apex of the curve, and end-point. The data were analyzed using Kolmogorov-Smirnov, analysis of variance, and Tukey tests. RESULTS The mean total width of the prepared canals in the Reciproc group was greater than the TF and S5 groups at halfway to the orifice, the beginning of the curve, the apex of the curve, and the end-point (P < 0.05). Mean absolute transportation was always <0.16 mm; however, significant differences occurred between the three systems at the orifice, halfway to the orifice, and the beginning of the curve (P < 0.05). TF created minimal absolute transportation at halfway to the orifice and the beginning of the curve, and greater absolute transportation at the orifice compared with the Reciproc and S5 instruments. However, the difference between the S5 and TF groups was not statistically significant at halfway to the orifice (P > 0.05). CONCLUSIONS Under the conditions of the study, Reciproc produced widest canal shapes. TF provided more centered apical preparation and maintained the original canal shape well.
منابع مشابه
Shaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth
Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...
متن کاملComparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...
متن کاملApically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.
INTRODUCTION The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. METHODS Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-...
متن کاملReciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-file Systems
BACKGROUND Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a...
متن کاملMicrotomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence.
INTRODUCTION A preparation technique with only 1 single instrument was proposed on the basis of the reciprocating movement of the F2 ProTaper instrument. The present study was designed to quantitatively assess canal preparation outcomes achieved by this technique. METHODS Twenty-five extracted human mandibular first molars with 2 separate mesial root canals were selected. Canals were randomly...
متن کامل