Clinical assessment of a rebreathing method for measuring pulmonary gas transfer.

نویسندگان

  • N J Russell
  • L R Bagg
  • J Dobrzynski
  • D T Hughes
چکیده

A rebreathing method for measuring carbon monoxide transfer factor (TLCO) and transfer coefficient (KCO) is evaluated. The test was performed on 42 subjects. Seventeen of these had normal lung function while the remainder suffered from various conditions, most having fibrosing alveolitis. No patients with severe airways obstruction were included in the group. The results were compared with single-breath measurements and close correlations were found between single-breath KCO and rebreathing KCO (r = 0.78, p less than 0.001) and between single-breath TLCO and rebreathing TLCO (r = 0.97, p less than 0.001). The reasons for discrepancies between single-breath and rebreathing values are discussed. It is concluded that measurement of rebreathing gas transfer is a useful supplement to routine tests of lung function, particularly in breathless patients with a small vital capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive measurement of pulmonary blood flow during prone positioning in patients with early acute respiratory distress syndrome.

In the daily clinical routine at the bedside, information on effective pulmonary blood flow (PBF) is limited and requires invasive monitoring, including a pulmonary artery catheter, to determine both cardiac output and intrapulmonary shunt. Therefore we evaluated a non-invasive method for the measurement of PBF in a clinical setting, including 12 patients with acute respiratory failure (acute r...

متن کامل

Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of ...

متن کامل

Effective pulmonary blood flow in normal children at rest.

Effective pulmonary blood flow was measured with a soluble inert gas uptake method (10% argon, 3.5% freon-22, 35% oxygen, balance nitrogen) in 98 apparently healthy children aged 5-14 years. None had any evidence of cardiorespiratory disease and all had normal values for absolute and dynamic lung volumes and transfer factor for carbon monoxide. Values of blood flow measured by a rebreathing met...

متن کامل

Comparison of cardiac output determined by a carbon dioxide-rebreathing and direct Fick method at rest and during exercise.

1. To study the validity of a CO2-rebreathing method at rest and during graded exercise, cardiac output was measured simultaneously on 59 occasions in 16 subjects with normal pulmonary function with the CO2-rebreathing method and the direct Fick method for oxygen. The correlation coefficient between the results of both methods was significantly higher during exercise than at rest. 2. No systema...

متن کامل

Sources of error in noninvasive pulmonary blood flow measurements by partial rebreathing: a computer model study.

BACKGROUND Partial rebreathing is a noninvasive method for measuring pulmonary blood flow (PBF). This study examines the systematic errors produced by the partial rebreathing technique utilizing a comprehensive mathematical model of the cardiorespiratory system of a healthy, 70-kg adult male. METHODS The model simulates tidal breathing through a branched respiratory tree and incorporates the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 38 3  شماره 

صفحات  -