Skin Contact Force Information in Sensory Nerve Signals Recorded by Implanted Cuff Electrodes

نویسندگان

  • Morten K. Haugland
  • J. Andy Hoffer
  • Thomas Sinkjaer
چکیده

When functional neuromuscular stimulation (FNS) is used to restore the use of paralyzed limbs after a spinal cord injury or stroke, it may be possible to control the stimulation using feedback information relayed by natural sensors in the skin. In this study we tested the hypothesis that the force applied on glabrous skin can be extracted from the electroneurographic (ENG) signal recorded from the sensory nerve. We used the central footpad of the cat hindlimb as a model of the human fingertip and recorded sensory activity with a cuff electrode chronically implanted around the tibial nerve. Our results showed that the tibial ENG signal, suitably liltered, recmed, and smoothed carries detailed static and dynamic information related to the force applied on the footpad. We derived a mathematical model of the force-ENG relation that provided accurate estimates of the ENG signal for a wide range of force proliles, amplitudes, and frequencies. Once fitted to data obtained in one recording session, the model could be made to fit data obtained in other sessions from the same cat, as well as from other cats, by simply adjusting its overall gain and offset. However, the model was noninvertible; i.e., the force could not be similarly predicted from the ENG signal, unless additional assumptions or restrictions were introduced. We discuss the reasons for these findings and their implications on the potential use of nerve signals as a source of continuous force feedback information suitable for closed-loop control of FNS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact-Free Sensory Nerve Signals Obtained from Cuff Electrodes During Functional Electrical Stimulation of Nearby Muscles

Restoration of the voluntary use of paralyzed limbs using functional neuromuscular stimulation (FNS) is limited by complex muscle properties and unpredictable load behaviors; closed-loop control of FNS would improve performance but requires reliable sensory feedback modalities. Sensory nerve signals recorded by cuff electrodes provide accurate information about forces acting on the skin in anes...

متن کامل

Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man.

A tetraplegic volunteer was implanted with percutaneous intramuscular electrodes in hand and forearm muscles. Furthermore, a sensory nerve cuff electrode was implanted on the volar digital nerve to the radial side of the index finger branching off the median nerve. In laboratory experiments a stimulation system was used to produce a lateral grasp (key grip) while the neural activity was recorde...

متن کامل

Spinal Evoked Potentials: Data and Experience

Peripheral Recording To monitor spinal cord function, peripheral input/output relationships _must be analyzed. Peripheral nerves are, therefore, important sites for stimulation and recording. As is typical for EPs, selection of electrodes and their use is essentially the same for stimulation and recording. There are several types of electrodes used for peripheral nerve stimulation or recording;...

متن کامل

Extraction of Sensory part of Ulnar Nerve Signal Using Blind Source Separation Method

A recorded nerve signal via an electrode is composed of many evokes or action potentials, (originated from individual axons) which may be considered as different initial sources. Recovering these primitive sources in its turn may lead us to the anatomic originations of a nerve signal which will give us outstanding foresights in neural rehabilitations. Accordingly, clinical interests may be r...

متن کامل

Experience with a hand grasp neuroprosthesis incorporating natural sensory feedback

This paper presents experience with a hand grasp neuroprosthesis that is controlled by means of signals from natural sensors in the skin. The signals from the natural sensors were recorded with a cuff electrode implanted around the palmar digital nerve innervating the radial aspect of the index finger. The implanted muscle stimulator is part of the commercial FREEHAND® System. A data-recording ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004