Osmotic pump implant for chronic infusion of drugs into the inner ear.

نویسندگان

  • J N Brown
  • J M Miller
  • R A Altschuler
  • A L Nuttall
چکیده

Continuous long-term delivery of experimental drugs to the cochlea of a small animal, such as a young guinea pig, presents several technical problems. A method of placing and securing a cannula-osmotic pump system is described in this paper. Guinea pigs (225-410 g) were unilaterally implanted with an Alzet micro-pump and cannula for delivery of 20 mM tetrodotoxin (TTX) (six animals) or saline (three animals) for three days (1 microliter/h). Auditory brainstem responses (ABRs) were recorded under light anesthesia on post-implant day 1 and day 3 and compared with pre-implant baseline values. In all six cochleas infused with TTX, most frequencies showed a 30-60dB decrease in sensitivity within 24 h. Saline control animals showed little or no change from baseline sensitivity for most frequencies. In three TTX-infused animals, the cannula-pump unit was removed on day 3, and ABRs were followed during recovery. Most frequencies returned to, or near, pre-implant levels after pump removal but recovery times varied. By day 6, all animals had recovered post-surgical weight loss and showed a gain of 10-40 g. Brains and cochleas were removed and processed for sectioning. Assessment of the cochlear nucleus of non-recovery TTX-treated animals showed a deafness-related flattening of auditory nerve active zones on the treated side.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local inner ear application of dexamethasone in cochlear implant models is safe for auditory neurons and increases the neuroprotective effect of chronic electrical stimulation

Dexamethasone (DEX) can reduce fibrous tissue growth as well as loss of residual hearing which may occur after cochlear implantation. Little is known about the effect of local inner ear DEX treatment on the spiral ganglion neurons (SGN), which are the target of the electrical stimulation with a cochlear implant (CI). Three different clinically relevant strategies of DEX-delivery into the inner ...

متن کامل

Use of Intrathecal Fluorescein in Recurrent Meningitis after Cochlear Implantation-A Case Report

Introduction: Congenital anomalies of the cochlea and labyrinth can be associated with meningitis and varying degrees of hearing loss or deafness. Despite antibiotics, meningitis remains a life threatening complication.   Case Report: We report a case of recurrent meningitis following episodes of otitis media in a cochlear implantee child with bilateral vestibulocochlear malformation, due to f...

متن کامل

Round Window Membrane and Delivery of Biologically Active Agents into the Cochlea

Establishing efficient methods for local administration of drugs to the inner ear has great clinical relevance for the management of inner ear disorders. However, the administration route remains a critical issue. The most feasible approach for a non invasive drug delivery to the inner ear is application of medication to the middle ear cavity on the promise that it will diffuse through the thin...

متن کامل

Morphological and physiological effects of long duration infusion of strychnine into the organ of Corti.

Acute strychnine administration has long been used as a method to eliminate the effects of efferent activity. It has been shown that long after termination of chronic strychnine infusion into the cochlea, the ear becomes more susceptible to acoustic trauma suggesting that chronic strychnine infusion results in long lasting or permanent disruption of efferent function. Much research has been dir...

متن کامل

A new electro-osmotic pump based on silica monoliths

A high-pressure electro-osmotic (EO) micro-pump fabricated by a sol–gel process is shown to be potentially effective as a fluid-driving unit on chip-scale analytical systems. A silica monolithic matrix with a morphology of micron-scaled through pores was synthesized within the 100 m inner diameter (i.d.) fused-silica capillary of the micro-pump. The monolith bonds directly with the capillary wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hearing research

دوره 70 2  شماره 

صفحات  -

تاریخ انتشار 1993