Accuracy of a New Platelet Count System (PLT-F) Depends on the Staining Property of Its Reagents
نویسندگان
چکیده
BACKGROUND Platelet count is essential for the diagnosis and management of hemostasis abnormalities. Although existing platelet count methods installed in common hematology analyzers can correctly count platelets in normal blood samples, they tend to miscount platelets in some abnormal samples. The newly developed PLT-F channel in the XN-Series hematology analyzer (Sysmex) has been reported to be a reliable platelet count system, even in abnormal samples. However, how the PLT-F platelet counting system achieves such accuracy has not been described in scientific articles. METHODS Isolated platelets, erythrocytes, and fragmented erythrocytes were examined using an automated hematology analyzer. The samples were labeled by combining PLT-F reagents and anti-CD62p, CD63, Grp75, Calreticulin, CD41, or CD61 antibody, and analyzed using confocal laser scanning microscopy or flow cytometry. RESULTS The PLT-F system correctly discriminated platelets in erythrocytes. Its reagents strongly stained some intraplatelet organelles labeled with anti-Grp75, but only faintly stained the plasma membrane of both platelets and erythrocytes. Microscopic observation and flow cytometric examination revealed that all of these strongly stained cells were also labeled with platelet-specific anti-CD41 and anti-CD61 antibodies. CONCLUSIONS This study revealed that the staining property of the PLT-F reagents, by which platelets and fragmented erythrocytes are clearly distinguished, contributes to the platelet-counting accuracy of the PLT-F system.
منابع مشابه
New fluorescent method (PLT-F) on Sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting.
OBJECTIVES In thrombocytopenia, high accuracy and precision of low platelet count is essential for appropriate decisions. The recently introduced Sysmex XN2000 analyzer (Sysmex, Kobe, Japan) offers 3 methods for platelet counting: impedance (PLT-I), optical (PLT-O), and a new fluorescence method (PLT-F). The precision of the PLT-F method in blood samples with platelet counts less than 50 × 10(3...
متن کاملThe Sysmex XN-2000 Hematology Autoanalyzer Provides a Highly Accurate Platelet Count than the Former Sysmex XE-2100 System Based on Comparison with the CD41/CD61 Immunoplatelet Reference Method of Flow Cytometry
Dear Editor The recently launched hematology autoanalyzer Sysmex XN2000 (Sysmex, Kobe, Japan) provides a new method (PLT-F method) for platelet counting based on a fluorescent RNA staining dye named oxazine [1, 2]. The main advantage of the XN2000’s PLT-F method over the former instrument XE-2100’s optical method (PLT-O method) is the ability to identify apoptotic white cells and not count them...
متن کاملAlteration of Platelet Indices in Young Children with Acute Pyelonephritis
Background Platelets have an important contribution in pathogenesis of different infectious and inflammatory disorders. This study was performed to identify the diagnostic value of platelet count (PLT), and platelet indices in children with acute pyelonephritis (APN). Materials and Methods In a cross sectional case control s...
متن کاملThe Air Bubbles and Foam in the Bag of Platelet: Effects on the Quality of the Final Product
Background and Aims: The quality of platelets (PLT) during storage is influenced by various factors. The purpose of this study was to determine the potential effects of the air bubbles and foam in the bag of platelet and its effects on the quality of the final product. Materials and Methods: In this paired-study, the air bubbles and foam, which develops after the preparation of the platelet un...
متن کاملEnhanced accuracy of optical platelet counts in microcytic anemia.
OBJECTIVE To determine whether microcytic erythrocytes influence the accuracy of automated platelet (PLT) counting. METHODS We divided a total of 206 K2 ethylenediaminetetraacetic acid (EDTA)-anticoagulated blood samples into 4 groups, as follows: In group 1 (control group), normal mean corpuscular volume (MCV > 80 fL) and PLT count equal or greater than 140,000/microL (n = 45); group 2, norm...