Earthquake locations and three-dimensional fault zone structure along the creeping section of the San Andreas fault near Parkfield, CA: Preparing for SAFOD
نویسندگان
چکیده
[1] Arrival-time data from 453 local earthquakes and 6 explosions at Parkfield, CA, are inverted for earthquake locations and three-dimensional Vp and Vp/Vs structure. The structure is dominated by the velocity contrast across the SAF, with the southwest side about 20–25% faster, consistent with previous studies. Nearly all the earthquakes occur almost directly beneath the fault trace. We find highVp/Vs anomalies that correlate with low-resistivity features in a magnetotelluric model that are interpreted to represent fluids. We locate a magnitude 2 earthquake that is a potential target event for the final stage of SAFOD drilling, yielding a depth of 3.1 km below surface and an epicenter 100 m southwest of the fault trace. Nonlinear analyses indicate 95%-confidence relative and absolute uncertainties on the order of 500–700 m vertically and 200–300 m horizontally for this target earthquake.
منابع مشابه
Strong tremor near Parkfield, CA, excited by the 2002 Denali Fault earthquake
[1] We show clear evidence of non-volcanic tremor triggered by 2002 Mw7.8 Denali Fault earthquake near Parkfield. Triggered tremor is identified as bursts of highfrequency ( 2–8 Hz), non-impulsive seismic energy whose envelope is coherent among many stations and has the same periodicity as the passing surface waves. The tremor originates from at least three hypocenters near the San Andreas faul...
متن کاملAnisotropy in the Shallow Crust Observed around the San Andreas Fault Before and After the 2004 M 6 . 0 Parkfield Earthquake
Local seismic arrays were deployed at two locations along the San Andreas fault (SAF) near Parkfield, California, before and after the 2004 M 6.0 Parkfield earthquake. Using local earthquakes we determine the anisotropic field within 1– 2 km of the main trace of the SAF at the two array locations separated by 12 km. The initial array, near the SAFOD site, was deployed for six weeks in October a...
متن کاملElectrical resistivity structure at the SAFOD site from magnetotelluric exploration
[1] The magnetotelluric dataset collected on the San Andreas Fault at Parkfield has been re-analyzed using superior inversion algorithms that have been developed in recent years. A combination of constrained inversion, forward modeling and synthetic inversion studies are used, and show that at the SAFOD site, the low resistivity fault zone extends to a depth of 2–3 km. An extended zone of low r...
متن کاملStreaks, multiplets, and holes: High-resolution spatio-temporal behavior of Parkfield seismicity
[1] Double-difference locations of 8000 earthquakes from 1969–2002 on the Parkfield section of the San Andreas Fault reveal detailed fault structures and seismicity that is, although complex, highly organized in both space and time. Distinctive features of the seismicity include: 1) multiple recurrence of earthquakes of the same size at precisely the same location on the fault (multiplets), imp...
متن کاملVariations of the velocity contrast and rupture properties of M6 earthquakes along the Parkfield section of the San Andreas fault
S U M M A R Y We investigate the seismic velocity contrast across the San Andreas fault (SAF) in the Parkfield area using fault zone head waves (FZHW) that propagate along the bimaterial fault interface and direct P waves. We systematically analyse large data sets of near-fault waveforms recorded by several seismic networks over the period 1984–2005. Clear FZHW are observed at many stations on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003