Analytical relations for long-droplet breakup in asymmetric T junctions.
نویسندگان
چکیده
We develop accurate analytical relations for the droplet volume ratio, droplet length during breakup process, and pressure drop of asymmetric T junctions with a valve in each of the branches for producing unequal-sized droplets. An important advantage of this system is that after manufacturing the system, the size of the generated droplets can be changed simply by adjusting the valves. The results indicate that if the valve ratio is smaller than 0.65, the system enters a nonbreakup regime. Also the pressure drop does not depend on the time and decreases by increasing the valve ratio, namely, opening the degree of valve 1 to valve 2. In addition, the results reveal that by decreasing (increasing) the valve ratio, the droplet length of branch 1 decreases (increases) and the droplet length of branch 2 increases (decreases) linearly while the whole length of the droplet remains unchanged.
منابع مشابه
Droplet breakup in an asymmetric microfluidic T junction.
Breakup of non-uniform droplets in an asymmetric T junction consisting of an inlet channel and two different-size outlet channels has been investigated numerically. Also, an analytical approach in the limit of the lubrication approximation has been extended to provide some analytical relations to study the system and verify the numerical results. Parameters that are important in the performance...
متن کاملLattice Boltzmann Simulation of Deformation and Breakup of a Droplet under Gravity Force Using Interparticle Potential Model
Abstract In this paper interparticle potential model of the lattice Boltzmann method (LBM) is used to simulate deformation and breakup of a falling droplet under gravity force. First this model is applied to ensure that the surface tension effect is properly implemented in this model. Two tests have been considered. First, it has been checked an initial square drop in a 2D domain can freely def...
متن کاملMonodispersed microfluidic droplet generation by shear focusing microfluidic device
A microfluidic device designed to generate monodispersed picoliter to femtoliter sized droplet emulsions at controlled rates is presented. This PDMS microfabricated device utilizes the geometry of the channel junctions in addition to the flow rates to control the droplet sizes. An expanding nozzle is used to control the breakup location of the droplet generation process. The droplet breakup occ...
متن کاملReduction of Parasitic Currents in Simulation of Droplet Secondary Breakup with Density Ratio Higher than 60 by InterDyMFoam
متن کامل
Droplet Breakup Dynamics in Bi-Layer Bifurcating Microchannel
Breakup of droplets at bi-layer bifurcating junction in polydimethylsiloxane (PDMS) microchannel has been investigated by experiments and numerical simulation. The pressure drop in bi-layer bifurcating channel was investigated and compared with single-layer bifurcating channel. Daughter droplet size variation generated in bi-layer bifurcating microchannel was analyzed. The correlation was propo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review. E, Statistical, nonlinear, and soft matter physics
دوره 91 5 شماره
صفحات -
تاریخ انتشار 2015