Comparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country.

نویسندگان

  • L K Archibald
  • L C McDonald
  • R M Addison
  • C McKnight
  • T Byrne
  • H Dobbie
  • O Nwanyanwu
  • P Kazembe
  • L B Reller
  • W R Jarvis
چکیده

In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Septi-Chek bacterial (SC-B) systems. During study period I, blood was inoculated at 5 ml into an MFL bottle, 10 ml into an Isolator tube for lysis and centrifugation, and 10 ml into an SC-B bottle. Next, 0.5-ml aliquots of Isolator concentrate were inoculated into an SC-AFB bottle and onto Middlebrook 7H11 agar slants, chocolate agar slants, and Inhibitory Mold Agar (IMA) slants. During study period II, the SC-B and chocolate agar cultures were discontinued. MFL growth was detected by fluorescence caused by shining UV light (lambda = 365 nm) onto the indicator on the bottom of the bottle. During study period I, 251 blood cultures yielded 44 bacterial isolates. For bacteremia, the MFL was similar to the Isolator concentrate on chocolate agar (34 of 44 versus 27 of 44; P, not significant [NS]), but more sensitive than the SC-B bottle (34 of 44 versus 24 of 44; P = 0.05). For both study periods combined, 486 blood cultures yielded 37 mycobacterial and 13 fungal isolates. For mycobacteremia, the sensitivities of the MFL and Isolator concentrate in the SC-AFB bottle were similar (30 of 37 versus 29 of 37; P, NS); the MFL bottle was more sensitive than the concentrate on Middlebrook agar (30 of 37 versus 15 of 37; P = 0.002). For fungemia, the MFL bottle was as sensitive as the SC-B bottle or Isolator concentrate on chocolate agar or IMA slants. We conclude that the MFL bottle, inoculated with just 5 ml of blood and examined under UV light, provides a sensitive and uncomplicated method for comprehensive detection of BSI in less-developed countries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.

To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube requi...

متن کامل

Controlled comparison of BacT/Alert MB system, manual Myco/F lytic procedure, and isolator 10 system for diagnosis of Mycobacterium tuberculosis Bacteremia.

We compared the performance of the BacT/Alert MB system, that of the manual Bactec Myco/F Lytic procedure, and that of the Isolator 10 lysis-centrifugation system in the detection of Mycobacterium tuberculosis bacteremia. Mean times to detection were 16.4 days for BacT/Alert MB versus 20.0 days for Myco/F Lytic, 16.5 days for BacT/Alert MB versus 23.8 days for Isolator 10, and 21.1 days for Bac...

متن کامل

Utility of paired BACTEC MYCO/F LYTIC blood culture vials for detection of bacteremia, mycobacteremia, and fungemia.

In previous bloodstream infection studies in Malawi, we inoculated blood from a single venesection into a single BACTEC MYCO/F LYTIC (MFL) vial. Inoculation of one vial, however, would be expected to reduce the sensitivity of bloodstream pathogen detection with MFL vials. To ascertain the degree of this loss of sensitivity, blood was drawn from each of 228 febrile, adult inpatients in Malawi an...

متن کامل

Evaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria and fungi from blood.

The reliability of MYCO/F Lytic medium in the BACTEC 9240 blood culture system was evaluated by comparing its performance to that of the Isolator system for the recovery of fungi and to that of the ESP II system for the recovery of mycobacteria. Of 717 specimens of blood cultured for fungi, 24 were positive; 12 samples were positive with both systems, 7 samples were positive with the Isolator s...

متن کامل

Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 38 8  شماره 

صفحات  -

تاریخ انتشار 2000