Value and limitations of peak-to-peak gradient for evaluation of aortic stenosis.
نویسندگان
چکیده
BACKGROUND AND AIM OF THE STUDY In patients with aortic stenosis (AS), it has been reported that the transvalvular pressure gradients (APs) may be reduced or even abolished in the presence of concomitant arterial hypertension, but the mechanisms underlying this phenomenon remain unclear. The study aim was to: (i) examine the relationship between systemic arterial hemodynamics and the peak-to-peak (deltaP(PtoP)), peak deltaP and mean deltaP; and (ii) propose and validate a new formula for the non-invasive estimation of the deltaP(PtoP) and of the peak left ventricular systolic pressure (LVSP) using Doppler echocardiography. METHODS Two fixed stenoses (geometric orifice area 1.0 and 1.35 cm2) and one bioprosthesis (effective orifice area (EOA) 1.2 cm2) were tested in a mock flow circulation model. Systemic vascular resistance (R) was increased from 1,500 to 3,300 dyne.s/cm5, and systemic arterial compliance (C) was decreased from 2.9 to 0.9 ml/mmHg, while transvalvular flow was held constant. RESULTS Neither C nor R had any significant impact on EOA, peak deltaP and mean deltaP. deltaP(PtoP) was decreased markedly, however, when C was reduced (bioprosthesis: -15 mmHg (-69%); orifice 1.35 cm2: -24 mmHg (-30%); cm2: (-13%)). Subsequently, an equation was proposed to predict deltaP(PtoP) from EOA, mean deltaP, and C measured by Doppler echocardiography. LVSP calculated by adding the predicted deltaP(Ptop) to systolic arterial pressure (SAP) was compared with LVSP measured directly in a dataset of 24 pigs with experimentally induced AS. There was a strong agreement between the estimated and measured LVSP (r = 0.97; mean absolute error 5 +/- 5 mmHg). CONCLUSION deltaP(Ptop) should not be used to evaluate AS severity because, as opposed to peak and mean deltaPs, it is highly influenced by C. The new non-invasive method proposed in this study to estimate the LVSP may be useful for obtaining a more accurate estimate of global LV afterload in patients with AS.
منابع مشابه
Impact of N-Terminal BNP levels in patients with severe valvar aortic stenosis
AIM The standard tool to evaluate and follow up patients with aortic stenosis is Echocardiography. Nevertheless, most of the current echocardiographic parameters have limitations in predicting symptom onset and clinical outcome. Association of BNP with symptom onset in aortic stenosis although validated may be used as a hemodynamic marker to predict outcome in severe AS. Aim is to investigate t...
متن کاملIs the Peak-to-Mean Pressure Gradient Ratio Useful for Assessment of Aortic Valve Prosthesis Obstruction?
BACKGROUND The evaluation of prosthetic valves is very difficult with two-dimensional transthoracic echocardiography alone. Doppler and color flow imaging as well as transesophageal echocardiography are more reliable to detect prosthetic valve dysfunction. However, Doppler study sometimes tends to be misleading due to the load-depending characteristics of peak and mean pressure gradients. The p...
متن کاملInaccuracies in using aortic valve gradients alone to grade severity of aortic stenosis.
The severity of aortic stenosis is an important determinant of prognosis in patients with symptoms who do not undergo valve replacement. To assess the pitfalls of using valve gradients alone 636 patients with aortic stenosis in whom the aortic valve area had been calculated by the Gorlin formula were studied. The correlation between valve area and aortic gradients was poor. No gradient was foun...
متن کاملAortic balloon dilatation for congenital aortic stenosis: report of 90 cases (1986-98).
OBJECTIVE To review 12 years of experience of balloon aortic valvoplasty in childhood. DESIGN Early and mid-term clinical and instrumental evaluation of 104 consecutive balloon aortic valvoplasties performed from 1986 to 1998. SETTING A tertiary referral centre for congenital heart disease. PATIENTS 90 patients with congenital aortic stenosis: 20 neonates (group 1), 16 infants (group 2), ...
متن کاملTwo-dimensional strain for the assessment of left ventricular function in low flow-low gradient aortic stenosis, relationship to hemodynamics, and outcome: a substudy of the multicenter TOPAS study.
BACKGROUND Decision making in patients with low flow-low gradient aortic stenosis mainly depends on the actual stenosis severity and left ventricular function, which is of prognostic importance. We used 2-dimensional strain parameters measured by speckle tracking at rest and during dobutamine stress echocardiography to document the extent of myocardial impairment, its relationship with hemodyna...
متن کاملبررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی
Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of heart valve disease
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2006