Marginal fit at cylinder-abutment interface before and after overcasting procedure.

نویسندگان

  • Luciana Martins Cres Moraes
  • Paulo Henrique Orlato Rossetti
  • Leylha Maria Nunes Rossetti
  • Ana Paula Ribeiro do Vale Pedreira
  • Accacio Lins do Valle
  • Wellington Cardoso Bonachela
چکیده

The aim of this study was to measure marginal fit at cylinder-abutment interface, before and after overcasting procedure. A hexagonal implant was fixed to a stainless steel base and a Estheticone-like abutment used during all the experiment. Before casting procedure, gold (Group I) and Ni-Cr-Be (Group II) premachined cylinders were tightened to the abutment with gold and titanium screws (in both groups), with 10Ncm and 20Ncm torque values for the same screw type. Vertical measures were taken at the light microscope (Mitutoyo 5050, Tokyo, Japan) three times in six different parts along the abutment-cylinder interface for each torque value. Cylinders were overcast with Ag-Pd (Group I) or Ni-Cr-Be (Group II) alloy. After casting, the same measures and torque values were repeated. Intragroup differences (10 or 20Ncm torque values, before and after casting) and intergroup differences (10 and 20Ncm torque values, before or after casting) were analyzed by the Paired t Test; (p<0.05). Intragroup differences were observed for G-I (gold, 20Ncm, titanium screw, p=0.044) and for G-II (Ni-Cr-Be, 10Ncm, gold screw, p=0.002). Intergroup differences only were not observed in the G-II group (Ni-Cr-Be, 10 and 20Ncm, titanium screw, p=0.534). Within the limits of this study, the following conclusions can be drawn: 1) Regardless of screw type, marginal misfit was higher for Ni-Cr-Be cylinders after casting, but within acceptable levels of fit; 2) The combination of gold cylinders with gold or titanium screws was the most effective to reduce marginal misfit; 3) Both screw types did not improve marginal fit of Ni-Cr-Be cylinders after overcastting, and 4) Although a 20Ncm torque improved marginal fit in all situations, its use is not recommended due to the increased risk of prosthesis failure. Ni-Cr-Be alloys may be successfully used in single-tooth implant restorations, with no damage to the fit between abutment and prosthetic cylinder.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Screw Type, Alloy and Cylinder Position on the Marginal Fit of Implant Frameworks before and after Laser Welding

UNLABELLED Misfit at the abutment-prosthetic cylinder interface can cause loss of preload, leading to loosening or fracture of gold and titanium screws. OBJECTIVES To evaluate the influence of screw type, alloy, and cylinder position on marginal fit of implant frameworks before and after laser welding. METHODS After Estheticone-like abutments were screwed to the implants, thirty plastic pro...

متن کامل

Use of base metal casting alloys for implant framework: marginal accuracy analysis.

The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromiu...

متن کامل

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

Sealing Capability and SEM Observation of the Implant-Abutment Interface

To evaluate the sealing capability of external hexagon implant systems and assess the marginal fit, two groups (n = 10 each) were employed: SIN (Sistema de Implantes Nacional, Brazil) and Osseotite, (Biomet 3i, USA). Sealing capability was determined by placing 0.7 μL of 1% acid-red solution in the implant wells before the torque of their respective abutments. Specimens were then placed into 2....

متن کامل

Evaluation of Electric Discharge Machining to achieve Passive Fit of Implant Superstructure: An in vitro Study

Objective: To evaluate marginal discrepancies between cast implant superstructure and EDM processed implant structure. Materials and methods: For the purpose of this study, an experimental model was prepared on which nine cast implant superstructure in nickel-chromium were fabricated which was then subjected to EDM processing. One-screw test was used to verify fit of superstructure both preand ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied oral science : revista FOB

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 2005