Cross contamination in dual inlet isotope ratio mass spectrometers
نویسندگان
چکیده
Since the early days of geochemical isotope ratio mass spectrometry there has always been the problem of cross contamination, i.e. the contamination of the sample gas with traces of reference gas (and vice versa) in a dual inlet system and the analyzer itself. This was attributable to valve leakages and could be corrected for. In modern leak-free machines this problem still influences the measurements by scale contraction. It limits the interlaboratory comparability to values unacceptable for, e.g. global carbon cycle investigations on atmospheric dCO2, with the need to integrate global datasets at a 0.01‰ precision level. No matter what the reason of apparent cross contamination (physical leakage, low pump efficiency, gas–wall interactions), we present a method to measure the actual cross contamination as well as algorithms to correct for it. By using isotopically enriched sample gas the effect on the reference gas is directly shown. Especially for biomedical applications, employing highly enriched materials, the nonlinear correction has to be applied. A long-time record of two machines shows the influence of vacuum breakage and the inlet system setup. We present a survey of cross contamination in some of the frequently used machines. The relatively poor raw results of two recent interlaboratory comparison experiments are explained in terms of cross contamination. Whereas the linear two-point normalization procedure considered by itself may be appropriate for some routine applications at natural isotope abundances, it always relies on relative d values of two reference materials. There is an urgent need to establish absolute values for all scale-determining reference materials. We recommend the use of cross contamination measurements to at least determine the isotopic composition of all normalization materials as long as absolute measurements are not available. In principle, the cross contamination measurements should be used as a diagnostic tool on a regular basis. (Int J Mass Spectrom 198 (2000) 45–61) © 2000 Elsevier Science B.V.
منابع مشابه
Use of nitrous oxide as a purge gas for automated nitrogen isotope analysis by the Rittenberg technique
An apparatus that operates with an isotope-ratio mass spectrometer to automatically perform nitrogen isotope analyses by the Rittenberg technique was modified to permit the use of nitrous oxide (N(2)O) instead of Freon (CCl(2)F(2) or CHClF(2)) for the purging of air prior to hypobromite oxidation of ammonium-N to N(2) in a plastic microplate. Analytical performance was unaffected by the modific...
متن کاملClumped isotope measurements of small carbonate samples using a high-efficiency dual-reservoir technique.
RATIONALE The measurement of multiply substituted isotopologues of CO2 derived from carbonate has allowed the reconstruction of paleotemperatures from a single phase (CaCO3 ), circumventing uncertainty inherent in other isotopic paleothermometers. Traditional analytical techniques require relatively large amounts of carbonate (3-8 mg per replicate), which limits the applicability of the clumped...
متن کاملMass spectrometric assay of stable isotopic enrichment for the estimation of protein turnover in man
The isotope ratio mass spectrometer Dual inlet double collector gas isotope ratio mass spectrometers by inherent design, possess a low resolving power but extremely high sensitivity. These specialized instruments are capable of precise estimates of the heavy isotopic content of pure, low molecular weight permanent gases such as H,, CO,, N, and SO,. For present purposes, consideration will be gi...
متن کاملMass spectrometric assay of stable isotopic enrichment for the estimation of protein turnover in man.
The isotope ratio mass spectrometer Dual inlet double collector gas isotope ratio mass spectrometers by inherent design, possess a low resolving power but extremely high sensitivity. These specialized instruments are capable of precise estimates of the heavy isotopic content of pure, low molecular weight permanent gases such as H,, CO,, N, and SO,. For present purposes, consideration will be gi...
متن کاملA robust and fast method of sampling and analysis of delta13C of dissolved inorganic carbon in ground waters.
The stable carbon isotopic composition of dissolved inorganic carbon (delta13C(DIC)) is traditionally determined using either direct precipitation or gas evolution methods in conjunction with offline gas preparation and measurement in a dual-inlet isotope ratio mass spectrometer. A gas evolution method based on continuous-flow technology is described here, which is easy to use and robust. Water...
متن کامل