Heated humidification or face mask to prevent upper airway dryness during continuous positive airway pressure therapy.
نویسندگان
چکیده
STUDY OBJECTIVES The objectives of this study were (1) to evaluate the way in which nasal continuous positive airway pressure (CPAP) therapy influences the relative humidity (rH) of inspired air; and (2) to assess the impact on rH of the addition of an integrated heated humidifier or a full face mask to the CPAP circuitry. DESIGN The studies were performed in 25 patients with obstructive sleep apnea syndrome receiving long-term nasal CPAP therapy and complaining of nasal discomfort. During CPAP administration, temperature and rH were measured in the mask either during a night's sleep for 8 patients or during a daytime study in which the effects of mouth leaks were simulated in 17 patients fitted with either a nasal mask (with or without humidification) or a face mask alone. SETTING University hospital sleep disorders center. MEASUREMENTS AND RESULTS Compared with the values obtained with CPAP alone, integrated heated humidification significantly increased rH during the sleep recording, both when the mouth was closed (60 +/- 14% to 81 +/- 14%, p < 0.01) and during mouth leaks (43 +/- 12% to 64 +/- 8%, p < 0.01). During the daytime study, a significant decrease in rH was observed with CPAP alone. Compared with the values measured during spontaneous breathing without CPAP (80 +/- 2%), the mean rH was 63 +/- 9% (p < 0.01) with the mouth closed and 39 +/- 9% (p < 0. 01) with the mouth open. The addition of heated humidification to CPAP prevented rH changes when the mouth was closed (82 +/- 12%), but did not fully prevent the rH decrease during simulation of mouth leaks (63 +/- 9%) compared with the control period (80 +/- 2%, p < 0. 01). Finally, attachment of a face mask to the CPAP circuitry prevented rH changes both with the mouth closed (82 +/- 9%) and with the mouth open (84 +/- 8%). CONCLUSIONS These data indicate that inhaled air dryness during CPAP therapy can be significantly attenuated by heated humidification, even during mouth leaks, and can be totally prevented by using a face mask.
منابع مشابه
Effect of Heated Humidification on Adherence to Continuous Positive Airway Pressure Therapy in Subjects With Obstructive Sleep Apnea and Nasopharyngeal Symptoms.
Numerous studies have demonstrated the efficacy of CPAP therapy for reducing symptoms (eg, daytime sleepiness), improving quality of life (QOL), reducing the risk of driving and occupational accidents, and preventing sequelae of obstructive sleep apnea (OSA), such as cardiovascular morbidity and mortality.1-3 Many patients have trouble complying with CPAP therapy even though it is effective.4 A...
متن کاملHumidified nasal continuous positive airway pressure in obstructive sleep apnoea.
Heated humidification of nasal continuous positive airway pressure (nCPAP) reduces upper airway symptoms and improves initial use in obstructive sleep apnoea syndrome (OSAS). The present study aimed to assess the effect of heated humidification of nCPAP on upper airway symptoms and initial use in obstructive sleep apnoea. This study was of a randomised, crossover design. Subjects with polysomno...
متن کاملEffect of heated humidification on compliance and quality of life in patients with sleep apnea using nasal continuous positive airway pressure.
STUDY OBJECTIVE To determine whether the addition of heated humidification at treatment initiation with nasal continuous positive airway pressure (CPAP) would lead to better CPAP compliance and improve quality of life and subjective sleepiness in patients with sleep apnea. DESIGN Randomized controlled trial. SETTING An academic sleep center located at a Veterans Affairs hospital. PATIENTS...
متن کاملUse of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome.
Nasal symptoms associated with the use of nasal continuous positive airway pressure (nCPAP) in obstructive sleep apnoea (OSA) can adversely impact on patients' tolerance, acceptance and adherence to nCPAP therapy. Regular use of heated humidification is effective in alleviating these symptoms and improve patient comfort. In a randomised, parallel, double-blinded, controlled study, the present a...
متن کاملImpact of a controlled heated breathing tube humidifier on sleep quality during CPAP therapy in a cool sleeping environment.
There are conflicting data on the effect of adding a heated humidifier to nasal continuous positive airway pressure (CPAP) therapy for patients with obstructive sleep apnoea syndrome (OSAS). The effects of heated humidification on sleep quality and treatment side-effects for patients who prefer a cold bedroom environment have not been studied. A randomised, controlled crossover trial involving ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 117 1 شماره
صفحات -
تاریخ انتشار 2000