Optimal Clinical Time for Reliable Measurement of Transcutaneous CO2 with Ear Probes: Counterbalancing Overshoot and the Vasodilatation Effect

نویسندگان

  • Christian Domingo
  • Elisa Canturri
  • Amalia Moreno
  • Humildad Espuelas
  • Laura Vigil
  • Manel Luján
چکیده

OBJECTIVES To determine the optimal clinical reading time for the transcutaneous measurement of oxygen saturation (SpO(2)) and transcutaneous CO(2) (TcPCO(2)) in awake spontaneously breathing individuals, considering the overshoot phenomenon (transient overestimation of arterial PaCO(2)). EXPERIMENTAL SECTION: Observational study of 91 (75 men) individuals undergoing forced spirometry, measurement of SpO(2) and TcPCO(2) with the SenTec monitor every two minutes until minute 20 and arterial blood gas (ABG) analysis. Overshoot severity: (a) mild (0.1-1.9 mm Hg); (b) moderate (2-4.9 mm Hg); (c) severe: (>5 mm Hg). The mean difference was calculated for SpO(2) and TcPCO(2) and arterial values of PaCO(2) and SpO(2). The intraclass correlation coefficient (ICC) between monitor readings and blood values was calculated as a measure of agreement. RESULTS The mean age was 63.1 ± 11.8 years. Spirometric values: FVC: 75.4 ± 6.2%; FEV(1): 72.9 ± 23.9%; FEV(1)/FVC: 70 ± 15.5%. ABG: PaO(2): 82.6 ± 13.2; PaCO(2): 39.9.1 ± 4.8 mmHg; SaO(2): 95.3 ± 4.4%. Overshoot analysis: overshoot was mild in 33 (36.3%) patients, moderate in 20 (22%) and severe in nine (10%); no overshoot was observed in 29 (31%) patients. The lowest mean differences between arterial blood gas and TcPCO(2) was -0.57 mmHg at minute 10, although the highest ICC was obtained at minutes 12 and 14 (>0.8). The overshoot lost its influence after minute 12. For SpO(2), measurements were reliable at minute 2. CONCLUSIONS The optimal clinical reading measurement recommended for the ear lobe TcPCO(2) measurement ranges between minute 12 and 14. The SpO(2) measurement can be performed at minute 2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran

The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...

متن کامل

Treatment of knee osteoarthritis with platelet-rich plasma in comparison with transcutaneous electrical nerve stimulation plus exercise: a randomized clinical trial

  Background: Osteoarthritis is a disabling musculoskeletal disease with no definite treatment. This study compared the effect of Platelet-rich plasma (PRP) and Transcutaneous Electrical Nerve Stimulation (TENS) plus exercise in the treatment of patients with knee joint osteoarthritis.   Methods : 54 eligible patients with knee osteoarthritis were randomly allocated into two groups. (IRCT201211...

متن کامل

THE EFFECT OF ELECTROSTIMULATION ON CALORIC-INDUCED NYSTAGMUS: A PRELIMINARY STUDY

The objective of this study was to describe the role of electrical stimulation in controlling peripheral vertigo. In a prospective study on 13 healthy volunteers, nystagmus was induced with caloric stimulation and the interval of nystagmus disappearance was recorded. This time indicates the basal response of vestibular end-organ. After caloric irrigation, pulsed signal was applied for each...

متن کامل

Comparative Use of Electromyography in the Evaluation of Electroacupuncture and Transcutaneous Electrical Neural Stimulation (TENS) Effect on Regeneration of Sciatic Nerve in Dog

Objective-To determine the effect of Electroacupuncture and Transcutaneous Electrical Neural Stimulation on Regeneration of Sciatic Nerve in Dog   Design - Experimental in vivo study. Animals - A total of 15 adult male mixed bred dogs, weighing 26±2.6 Kg/BW with aging of 42±6 months, which were divided into three groups of  5 dogs. Procedures-Under general anesthesia, the right sciatic nerv...

متن کامل

CO2 Measurement of Synthetic Biogas by Passing It through Dilute NaOH Solution

The feasibility of measuring CO2 content in biogas was evaluated in this research. Firstly, Curtipot pH simulator was used to visualize the titration behaviors of various percentages of dissolved CO2 in a wide range of concentrations of NaOH solution. As a general output of those simulations, it was shown that when the titration curves of different CO2 conte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010