OBJECTIVES To determine the optimal clinical reading time for the transcutaneous measurement of oxygen saturation (SpO(2)) and transcutaneous CO(2) (TcPCO(2)) in awake spontaneously breathing individuals, considering the overshoot phenomenon (transient overestimation of arterial PaCO(2)). EXPERIMENTAL SECTION: Observational study of 91 (75 men) individuals undergoing forced spirometry, measurement of SpO(2) and TcPCO(2) with the SenTec monitor every two minutes until minute 20 and arterial blood gas (ABG) analysis. Overshoot severity: (a) mild (0.1-1.9 mm Hg); (b) moderate (2-4.9 mm Hg); (c) severe: (>5 mm Hg). The mean difference was calculated for SpO(2) and TcPCO(2) and arterial values of PaCO(2) and SpO(2). The intraclass correlation coefficient (ICC) between monitor readings and blood values was calculated as a measure of agreement. RESULTS The mean age was 63.1 ± 11.8 years. Spirometric values: FVC: 75.4 ± 6.2%; FEV(1): 72.9 ± 23.9%; FEV(1)/FVC: 70 ± 15.5%. ABG: PaO(2): 82.6 ± 13.2; PaCO(2): 39.9.1 ± 4.8 mmHg; SaO(2): 95.3 ± 4.4%. Overshoot analysis: overshoot was mild in 33 (36.3%) patients, moderate in 20 (22%) and severe in nine (10%); no overshoot was observed in 29 (31%) patients. The lowest mean differences between arterial blood gas and TcPCO(2) was -0.57 mmHg at minute 10, although the highest ICC was obtained at minutes 12 and 14 (>0.8). The overshoot lost its influence after minute 12. For SpO(2), measurements were reliable at minute 2. CONCLUSIONS The optimal clinical reading measurement recommended for the ear lobe TcPCO(2) measurement ranges between minute 12 and 14. The SpO(2) measurement can be performed at minute 2.
منابع مشابه
The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran
The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...
متن کاملTreatment of knee osteoarthritis with platelet-rich plasma in comparison with transcutaneous electrical nerve stimulation plus exercise: a randomized clinical trial
Background: Osteoarthritis is a disabling musculoskeletal disease with no definite treatment. This study compared the effect of Platelet-rich plasma (PRP) and Transcutaneous Electrical Nerve Stimulation (TENS) plus exercise in the treatment of patients with knee joint osteoarthritis. Methods : 54 eligible patients with knee osteoarthritis were randomly allocated into two groups. (IRCT201211...
متن کاملTHE EFFECT OF ELECTROSTIMULATION ON CALORIC-INDUCED NYSTAGMUS: A PRELIMINARY STUDY
The objective of this study was to describe the role of electrical stimulation in controlling peripheral vertigo. In a prospective study on 13 healthy volunteers, nystagmus was induced with caloric stimulation and the interval of nystagmus disappearance was recorded. This time indicates the basal response of vestibular end-organ. After caloric irrigation, pulsed signal was applied for each...
متن کاملComparative Use of Electromyography in the Evaluation of Electroacupuncture and Transcutaneous Electrical Neural Stimulation (TENS) Effect on Regeneration of Sciatic Nerve in Dog
Objective-To determine the effect of Electroacupuncture and Transcutaneous Electrical Neural Stimulation on Regeneration of Sciatic Nerve in Dog Design - Experimental in vivo study. Animals - A total of 15 adult male mixed bred dogs, weighing 26±2.6 Kg/BW with aging of 42±6 months, which were divided into three groups of 5 dogs. Procedures-Under general anesthesia, the right sciatic nerv...
متن کاملCO2 Measurement of Synthetic Biogas by Passing It through Dilute NaOH Solution
The feasibility of measuring CO2 content in biogas was evaluated in this research. Firstly, Curtipot pH simulator was used to visualize the titration behaviors of various percentages of dissolved CO2 in a wide range of concentrations of NaOH solution. As a general output of those simulations, it was shown that when the titration curves of different CO2 conte...
متن کامل