Endoresection of choroidal melanoma using high- frequency electric welding of biological tissues

نویسندگان

  • N. N. Umanets
  • Cand Sc Med
  • N. V. Pasyechnikova
  • V. A. Naumenko
چکیده

E-mail: [email protected] Background: The evolution of ocular oncology over the recent decades has been characterized by the emphasis on organ saving approaches, the main method requirement being the greatest degree of radicalism of tumor resection with a minimum amount of damage to surrounding tissues. Purpose: To assess the efficacy of endoresection for uveal melanoma, with the high-frequency electric welding used for achievement of hemostasis. Materials and Methods: Twenty patients (21 eyes; age, 51.6 (12.43) years) with choroidal melanoma were under our observation during 2010 to 2014. Prior to any treatment, the maximum tumor thickness based on ultrasound examination (Cine Scan) was 5.4 (2.6) mm (range, 1.4 mm to 10 mm), with the mean largest basal tumor diameter of 10.8 (3.7) mm (range, 7.6 mm to 15.8 mm). Patients underwent strontium-90 brachytherapy plus transpupillary thermotherapy to devitalize the tumor. Two months to 3 years thereafter, they underwent a 20-G three-port vitrectomy during which endoresection of melanoma was performed. Results: In 19 eyes (90%), massive hemorrhage from uveal melanoma vessles and choroidal vessels was observed during excision of tumor tissue, and was successfully resolved with high-frequency electric welding using a unipolar endovitreal probe. All patients were still alive at the end of observation period of 2 to 6 years. Two of them underwent enucleation due to progressive tumor growth and due to subacute uveitis and phthisis bulbi, respectively. Conclusions: Endoresection is an alternative technique for the treatment of uveal melanoma, with the eye salvage rate as high as 90%. The use of high-frequency electric welding of biological tissues in endoresection of uveal melanoma allowed us to avoid choroidal and ciliary hemorrhage in all cases, thus reducing the risk of intraand post-operative complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recurrence and massive extraocular extension of choroidal malignant melanoma after vitrectomy and endoresection

Vitrectomy and endoresection is an alternative to enucleation for the treatment of large malignant choroidal melanoma. We report a rare case of extensive recurrence of choroidal malignant melanoma with extraocular extension 11 years after surgical endoresection without adjuvant treatment.

متن کامل

Clinical procedure for intraocular electrochemical lysis during endoresection

Optimal clinical approaches to the treatment of large intraocular lesions located in the posterior pole of the eye remain controversial. In our opinion, the introduction of innovative techniques into the clinical practice of vitreoretinal surgery professionals as well as the implementation of new techniques designed to destroy tumour tissue will make endoresection one of the most promising alte...

متن کامل

Local treatment failure after globe-conserving therapy for choroidal melanoma

Local treatment failure after globe-conserving therapy for choroidal melanoma is a surgical complication with significant morbidity to the vision and eye. Few reports in the literature have addressed this complication exclusively. A review of the published literature with reference to local treatment failure in the management of choroidal melanoma was performed to make known the potential diffe...

متن کامل

Outcomes of primary endoresection for choroidal melanoma

Purpose To review long time treatment results in patients with small or medium sized choroidal melanoma who underwent surgical tumor endoresection as a primary treatment when plaque radiotherapy was unable and patients declined enucleation. Materials and methods Patients were evaluated for best corrected visual acuity (BCVA), and underwent biomicroscopy, indirect ophthalmoscopy, retinography ...

متن کامل

Preliminary results of proton radiotherapy for choroidal melanoma – the Kraków experience

AIM OF THE STUDY The objective of the study was to present the preliminary results of proton radiotherapy as a method for treating 15 patients with choroidal melanoma. MATERIAL AND METHODS The proton radiotherapy was administered using beams providing energy levels of 60 MeV, which ensures a clinical range of 28.4 mm. In addition, the beam has a very narrow penumbra of 1.3 mm and a sharp dist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016