Palpation force modulation strategies to identify hard regions in soft tissue organs
نویسندگان
چکیده
This paper presents experimental evidence for the existence of a set of unique force modulation strategies during manual soft tissue palpation to locate hard abnormalities such as tumors. We explore the active probing strategies of defined local areas and outline the role of force control. In addition, we investigate whether the applied force depends on the non-homogeneity of the soft tissue. Experimental results on manual palpation of soft silicone phantoms show that humans have a well defined force control pattern of probing that is used independently of the non-homogeneity of the soft tissue. We observed that the modulations of lateral forces are distributed around the mean frequency of 22.3 Hz. Furthermore, we found that the applied normal pressure during probing can be modeled using a second order reactive autoregressive model. These mathematical abstractions were implemented and validated for the autonomous palpation for different stiffness parameters using a robotic probe with a rigid spherical indentation tip. The results show that the autonomous robotic palpation strategy abstracted from human demonstrations is capable of not only detecting the embedded nodules, but also enhancing the stiffness perception compared to static indentation of the probe.
منابع مشابه
Correction: Palpation force modulation strategies to identify hard regions in soft tissue organs
[This corrects the article DOI: 10.1371/journal.pone.0171706.].
متن کاملEvaluation of stiffness feedback for hard nodule identification on a phantom silicone model
Haptic information in robotic surgery can significantly improve clinical outcomes and help detect hard soft-tissue inclusions that indicate potential abnormalities. Visual representation of tissue stiffness information is a cost-effective technique. Meanwhile, direct force feedback, although considerably more expensive than visual representation, is an intuitive method of conveying information ...
متن کاملParameter Estimation for a Mechatronic Probe of Robot assisted Minimally Invasive Surgery Using Inverse Finite Element Analysis
There is a need to provide haptic and tactile feedback to surgeons during robot-assisted minimally invasive surgery (RMIS). Such feedback is also essential for palpation based diagnostic during cancer removal using MIS. There have been recent efforts at developing a mechatronic finger to mimic some of the palpation capabilities of a human finger. These mechatronic fingers typically record force...
متن کاملReal-Time Elastography of the Prostate
Palpation of organs is one of the oldest clinical examination techniques, for instance, if you think of the palpation of the breast or the digital rectal examination of the prostate, where hard palpable regions are suspicious for cancer. This is the basic principle of real-time elastography, an ultrasound technique, which is able to visualise tissue elasticity. Since prostate cancer features an...
متن کاملUltrasound palpation sensor for tissue thickness and elasticity measurement--assessment of transverse carpal ligament.
Palpation is a traditional diagnostic procedure for health care professionals to use their fingers to touch and feel the body soft tissues. It is a common clinical approach, though it is rather subjective and qualitative and the palpation results may vary among different people. Tissue ultrasound palpation sensor (TUPS) provides a feasible solution that makes the palpation of soft tissues not s...
متن کامل