Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors

نویسندگان

  • Martin Andersson
  • Lennart Johansson
  • David Minarik
  • Sigrid Leide-Svegborn
  • Sören Mattsson
چکیده

BACKGROUND Effective dose represents the potential risk to a population of stochastic effects of ionizing radiation (mainly lethal cancer). In recent years, there have been a number of revisions and updates influencing the way to estimate the effective dose. The aim of this work was to recalculate the effective dose values for the 338 different radiopharmaceuticals previously published by the International Commission on Radiological Protection (ICRP). METHOD The new estimations are based on information on the cumulated activities per unit administered activity in various organs and tissues and for the various radiopharmaceuticals obtained from the ICRP publications 53, 80 and 106. The effective dose for adults was calculated using the new ICRP/International Commission on Radiation Units (ICRU) reference voxel phantoms and decay data from the ICRP publication 107. The ICRP human alimentary tract model has also been applied at the recalculations. The effective dose was calculated using the new tissue weighting factors from ICRP publications 103 and the prior factors from ICRP publication 60. The results of the new calculations were compared with the effective dose values published by the ICRP, which were generated with the Medical Internal Radiation Dose (MIRD) adult phantom and the tissue weighting factors from ICRP publication 60. RESULTS For 79% of the radiopharmaceuticals, the new calculations gave a lower effective dose per unit administered activity than earlier estimated. As a mean for all radiopharmaceuticals, the effective dose was 25% lower. The use of the new adult computational voxel phantoms has a larger impact on the change of effective doses than the change to new tissue weighting factors. CONCLUSION The use of the new computational voxel phantoms and the new weighting factors has generated new effective dose estimations. These are supposed to result in more realistic estimations of the radiation risk to a population undergoing nuclear medicine investigations than hitherto available values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to: Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors

1. For 79 % of the radiopharmaceuticals, the new calculations gave a lower effective dose per unit administered activity than earlier estimated.” Should be “For 63 % of the radiopharmaceuticals, the new calculations gave a lower effective dose per unit administered activity than earlier estimated.” 2. “As a mean for all radiopharmaceuticals, the effective dose was 25 % lower.” Should be“As a me...

متن کامل

Internal dosimetry of radioiodine using ICRP reference phantoms and updated biokinetic model

The purpose of this study is to estimate internal dose to human body due to administration of I-131 using new biokinetic model of iodine. In this respect, we used international commission on radiological protection (ICRP) adult reference phantoms. Monte Carlo calculations were performed using MCNPX 2.6 code. The average dose to target organ per disintegration inside source organ, namely S facto...

متن کامل

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

BACKGROUND To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protectio...

متن کامل

Radiation Risk Estimates in Indian Patients Due to Nuclear Cardiac Investigations

Radiation dose estimation due to administration of Tc-MIBI, 99m Tc-Tetrofosmin and TlCl is carried out using MIRD Scheme on anatomical consideration and tissue weighting factors for the Indian adult. The estimated radiation dose from these radiopharmaceuticals is about 12-14 % more as compared to ICRP adult on anatomical consideration alone and is attributed to smaller body weight and smaller o...

متن کامل

SU-E-I-40: Effective Dose Normalized to Dose Length Product for Pediatric and Adult Reference Phantoms in Computed Tomography Examinations.

PURPOSE To develop a set of conversion factors from dose length product (DLP) to effective dose (E) for pediatric and adult reference individuals undergoing computed tomography (CT) examinations. METHODS This study used 12 hybrid computational phantoms representing reference pediatric and adult individuals in compliance with the International Commission on Radiological Protection (ICRP) refer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014