Endoluminal surface registration for CT colonography using haustral fold matching☆

نویسندگان

  • Thomas Hampshire
  • Holger Roth
  • Emma Helbren
  • Andrew Plumb
  • Darren Boone
  • Gregory G. Slabaugh
  • Steve Halligan
  • David J. Hawkes
چکیده

Computed Tomographic (CT) colonography is a technique used for the detection of bowel cancer or potentially precancerous polyps. The procedure is performed routinely with the patient both prone and supine to differentiate fixed colonic pathology from mobile faecal residue. Matching corresponding locations is difficult and time consuming for radiologists due to colonic deformations that occur during patient repositioning. We propose a novel method to establish correspondence between the two acquisitions automatically. The problem is first simplified by detecting haustral folds using a graph cut method applied to a curvature-based metric applied to a surface mesh generated from segmentation of the colonic lumen. A virtual camera is used to create a set of images that provide a metric for matching pairs of folds between the prone and supine acquisitions. Image patches are generated at the fold positions using depth map renderings of the endoluminal surface and optimised by performing a virtual camera registration over a restricted set of degrees of freedom. The intensity difference between image pairs, along with additional neighbourhood information to enforce geometric constraints over a 2D parameterisation of the 3D space, are used as unary and pair-wise costs respectively, and included in a Markov Random Field (MRF) model to estimate the maximum a posteriori fold labelling assignment. The method achieved fold matching accuracy of 96.0% and 96.1% in patient cases with and without local colonic collapse. Moreover, it improved upon an existing surface-based registration algorithm by providing an initialisation. The set of landmark correspondences is used to non-rigidly transform a 2D source image derived from a conformal mapping process on the 3D endoluminal surface mesh. This achieves full surface correspondence between prone and supine views and can be further refined with an intensity based registration showing a statistically significant improvement (p<0.001), and decreasing mean error from 11.9 mm to 6.0 mm measured at 1743 reference points from 17 CTC datasets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Prone to Supine Haustral Fold Matching in CT Colonography Using a Markov Random Field Model

CT colonography is routinely performed with the patient prone and supine to differentiate fixed colonic pathology from mobile faecal residue. We propose a novel method to automatically establish correspondence. Haustral folds are detected using a graph cut method applied to a surface curvature-based metric, where image patches are generated using endoluminal CT colonography surface rendering. T...

متن کامل

Endoluminal surface registration for CT colonography using haustral fold matchingq

Computed Tomographic (CT) colonography is a technique used for the detection of bowel cancer or potentially precancerous polyps. The procedure is performed routinely with the patient both prone and supine to differentiate fixed colonic pathology from mobile faecal residue. Matching corresponding locations is difficult and time consuming for radiologists due to colonic deformations that occur du...

متن کامل

Prone to Supine CT Colonography Registration Using a Landmark and Intensity Composite Method

Matching corresponding location between prone and supine acquisitions for CT colonography (CTC) is essential to verify the existence of a polyp, which can be a difficult task due to the considerable deformations that will often occur to the colon during repositioning of the patient. This can induce error and increase interpretation time. We propose a novel method to automatically establish corr...

متن کامل

City Research Online Registration of the Endoluminal Surfaces of the Colon Derived from Prone and Supine Ct Colonography Registration of the Endoluminal Surfaces of the Colon Derived from Ctc

Purpose: Computed tomographic (CT) colonography is a relatively new technique for detecting bowel cancer or potentially precancerous polyps. CT scanning is combined with 3-dimensional image reconstruction to produce a virtual endoluminal representation similar to optical colonoscopy. Because retained fluid and stool can mimic pathology, CT data is acquired with the bowel cleansed and insufflate...

متن کامل

Registration of the endoluminal surfaces of the colon derived 1 from prone and supine CT colonography

Purpose: Computed tomographic (CT) colonography is a relatively new technique for detecting bowel cancer or potentially precancerous polyps. CT scanning is combined with 3-dimensional image reconstruction to produce a virtual endoluminal representation similar to optical colonoscopy. Because retained fluid and stool can mimic pathology, CT data is acquired with the bowel cleansed and insufflate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2013