Numerical simulation of in vivo intraosseous torsional failure of a hollow-screw oral implant

نویسندگان

  • Murat Cehreli
  • Murat Akkocaoglu
  • Kivanc Akca
چکیده

BACKGROUND Owing to the complexity and magnitude of functional forces transferred to the bone-implant interface, the mechanical strength of the interface is of great importance. The purpose of this study was to determine the intraosseous torsional shear strength of an osseointegrated oral implant using 3-D finite element (FE) stress analysis implemented by in vivo failure torque data of an implant. METHODS A Ø 3.5 mm x 12 mm ITI hollow screw dental implant in a patient was subjected to torque failure test using a custom-made strain-gauged manual torque wrench connected to a data acquisition system. The 3-D FE model of the implant and peri-implant circumstances was constructed. The in vivo strain data was converted to torque units (N x cm) to involve in loading definition of FE analysis. Upon processing of the FE analysis, the shear stress of peri-implant bone was evaluated to assume torsional shear stress strength of the bone-implant interface. RESULTS The in vivo torque failure test yielded 5952 microstrains at custom-made manual torque wrench level and conversion of the strain data resulted in 750 N.cm. FE revealed that highest shear stress value in the trabecular bone, 121 MPa, was located at the first intimate contact with implant. Trabecular bone in contact with external surface of hollow implant body participated shear stress distribution, but not the bone resting inside of the hollow. CONCLUSION The torsional strength of hollow-screw implants is basically provided by the marginal bone and the hollow part has negligible effect on interfacial shear strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Stress Intensity Factors in Hollow Cylinders Reinforced by an Effective Coating Containing Multiple Cracks

In this paper, the solution of an isotropic hollow cylinder, with an isotropic coating, weakened by multiple radial cracks is studied. The hollow cylinder and its coating are under Saint-Venant torsional loading. The series solution is then derived for displacement and stress fields in the cross section of the cylinder containing a Volterra-type screw dislocation. The dislocation solution is em...

متن کامل

Comparative study of two different implants with hexogonal connection on the amount of bacteria accumulated at the implant platform site: An in-vivo study

Background and Aims: Nowadays, the best choice for replacing missing teeth are dental implants, however, failure is not unexpected. One of the factors that plays an important role in the implant failure is bacterial microleakage which could cause biological complication. The aim of this study was to compare the bacterial microleakage between the two types of implants. Materials and Methods:...

متن کامل

Tissue reactions, fluids, and bacterial infiltration in implants retrieved at autopsy: a case report.

A 72-year-old patient underwent the placement of 2 screw-type implants. After 5 months the patient died of a massive stroke, and a block section of the portion of the mandible containing the implants was done. The specimen was treated to obtain thin ground sections. A 1- to 5-micron gap was present between the implant and the healing cover screw, and this space was filled by bacteria and calcul...

متن کامل

Cement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration

Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...

متن کامل

Generalized solution of functionally graded hollow cylinder under torsional load

In this paper, a general solution for torsion of hollow cylinders made of functionally graded materials (FGM) was investigated. The problem was formulated in terms of Prandtl’s stress and, in general, the shear stress and angle of twist were derived. Variations in the material properties such as Young’s modulus and Poisson’s ratio might be arbitrary functions of the radial coordinate. Various m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Head & Face Medicine

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2006