Automated cuff occlusion pressure effect on quality of operative fields in foot and ankle surgery: a randomized prospective study.

نویسندگان

  • Alastair Se Younger
  • Mojieb Manzary
  • Kevin J Wing
  • Keith Stothers
چکیده

BACKGROUND Limb occlusion pressure, which is present when blood flow ceases, has not had a practical method described for attainment. An automated tourniquet system was modified to set tourniquet pressure based on measurement of limb occlusion pressure (LOP). In this single surgeon randomized prospective study, the effectiveness of this system was assessed on patients undergoing foot and ankle surgery. MATERIALS AND METHODS Two hundred forty-four patients were randomized to the study group of automated pressure (n = 112) or to the control group (n = 132). The primary outcome measure was tourniquet pressure used for either group. Secondary measures included the time to set the pressure and number of patients failing LOP measurement. The tourniquet field was assessed intraoperatively and postoperatively in a blinded manner. RESULTS The tourniquet pressure was significantly lower in the study group at 198.5 ± 20.2 mmHg compared to 259.6 ± 4.4 in the control group (p < 0.001). The time to measure the LOP was 20 ± 6 seconds. Six patients failed to be measured. The quality of the surgical field was judged to be better in the study group based on all three methods of assessment. CONCLUSION LOP measurement was a practical way of setting tourniquet pressures for limb surgery. The automated pressure averages were lower than those routinely used by most surgeons for thigh tourniquets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF CHANGE IN POSITION ON INTRATRACHEAL CUFF PRESSURE IN PATIENTS UNDERGOING SURGERY WITH GENERAL ANESTHESIA: A PROSPECTIVE ANALYTICAL STUDY

Background & Aims: Tracheal intubation with a cuffed tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent aspiration and leakage of air and anesthetic gases. Whereas over-inflation can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. This study aimed to evaluate ...

متن کامل

Operating Room Time Savings with the Use of Splint Packs: A Randomized Controlled Trial

 Background: The most expensive variable in the operating room (OR) is time. Lean Process Management is being used in the medical field to improve efficiency in the OR. Streamlining individual processes within the OR is crucial to a comprehensive time saving and cost-cutting health care strategy. At our institution, one hour of OR time costs approximately $500, exclusive of supply and personnel...

متن کامل

Survey of tourniquet use in orthopaedic foot and ankle surgery.

BACKGROUND Tourniquet technique varies among foot and ankle surgeons, and to establish a standard practice guideline the current standard of care should be examined. METHODS One hundred and forty responses were received after 253 surveys were mailed to American Orthopaedic Foot and Ankle Society (AOFAS) members, concerning type of tourniquets, location, and pressures used. RESULTS Cuff pres...

متن کامل

Effect of Positioning on the Pressure of Endotracheal Tube Cuff Filled with Air versus Saline: A Double-blind Randomized Clinical Trial

Background: Control and maintenance of endotracheal tube cuff pressure and prevention of sore throat are major concerns in post-anesthesia care. Aim: This study aimed to evaluate changes in the pressure of the endotracheal tube cuff filled with saline versus air and post-anesthesia sore throat when the position is altered from supine to lateral. <st...

متن کامل

Wide contoured thigh cuffs and automated limb occlusion measurement allow lower tourniquet pressures.

We examined the amount of thigh tourniquet pressure that can be reduced from the typical 300 to 350 mm Hg by using a new automated plethysmographic limb occlusion pressure measurement technique. We also examined how much pressure could be reduced by using a wide contoured cuff compared with a standard cuff and if limb occlusion and systolic blood pressures were well correlated. Patients having ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 2011