Phase-sensitive inversion recovery (PSIR) single-shot TrueFISP for assessment of myocardial infarction at 3 tesla.

نویسندگان

  • Armin Huber
  • Kerstin Bauner
  • Bernd J Wintersperger
  • Scott B Reeder
  • Frank Stadie
  • Edgar Mueller
  • Michaela Schmidt
  • Eva Winnik
  • Maximilian F Reiser
  • Stefan O Schoenberg
چکیده

PURPOSE The aim of the current study was to show if contrast-to-noise ratio (CNR) could be improved without loss of diagnostic accuracy if a phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence is used at 3.0 T instead of 1.5 T. MATERIAL AND METHODS Ten patients with myocardial infarction were examined on a 1.5 T magnetic resonance (MR) system (Avanto, Siemens Medical Systems) and at a 3.0 T MR system. Imaging delayed contrast enhancement was started 10 minutes after application of contrast material. A phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence was used at 1.5 and 3.0 T and compared with a segmented IR turboFLASH sequence at 1.5 T, which served as the reference method. Infarct volumes and CNR of infarction and normal myocardium were compared with the reference method. RESULTS The PSIR Single-Shot TrueFISP technique allows for imaging nine slices during a single breathhold without adaptation of the inversion time. The mean value of CNR between infarction and normal myocardium was 5.9 at 1.5 T and 12.2 at 3.0 T (magnitude images). The CNR mean value of the reference method was 8.4. The CNR mean value at 3.0 T was significantly (P = 0.03) higher than the mean value of the reference method. The correlation coefficients of the infarct volumes, determined with the PSIR single-shot TrueFISP technique at 1.5 T and at 3.0 T and compared with the reference method, were r = 0.96 (P = 0.001) and r = 0.99 (P = 0.0001). CONCLUSION The use of PSIR single-shot TrueFISP at 3.0 T allows for accurate detection and assessment of myocardial infarction. CNR is significantly higher at 3.0 T compared with 1.5 T. The PSIR single-shot technique at 3.0 T provides a higher CNR than the segmented reference technique at 1.5 T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of phase and magnitude images using PSIR sequence in the study of infarct size with delayed-enhancement cardiac magnetic resonance imaging at 3 Tesla

Delayed-Enhancement Cardiac Magnetic Resonance (DE-CMR) imaging with a gadolinium-based contrast agent strongly correlates with infarct size [1] and is a major tool for the assessment of myocardial viability [2]. A phase-sensitive inversion-recovery (PSIR) technique has been described at 1.5 T for assessment of myocardial infarct size [3]. With this technique, the signal polarity of the inversi...

متن کامل

The validity of a free breathing motion corrected phase sensitive inversion recovery sequence in the detection of delayed myocardial enhancement in non-ischemic heart disease

Background Breath-hold (BH) segmented TURBO FLASH (TFL) is currently used as the gold standard technique to evaluate delayed enhancement (DE) of the myocardium, typically with a phase sensitive inversion recovery (PSIR) approach (1). However, many patients are unable to perform adequate breath-holding resulting in poor image quality and limited diagnostic yield. Free breathing (FB) single shot ...

متن کامل

Comparison of image quality and acquistion time of Free-Breathing (FB) motion corrected (MOCO) SSFP to current PSIR sequences: is one sequence superior?

Background Delayed myocardial enhancement (DE) sequences have become essential in cardiac MRI (CMRI) for visualization of abnormal myocardium. DE sequences require an inversion pulse to null normal myocardium, and the introduction of phase-sensitive inversion recovery (PSIR) sequences, which are less sensitive to small variations in inversion time (TI), have provided a suitable alternative to m...

متن کامل

Motion-corrected free-breathing delayed enhancement imaging of myocardial infarction.

Following administration of Gd-DTPA, infarcted myocardium exhibits delayed enhancement and can be imaged using an inversion-recovery sequence. A conventional segmented acquisition requires a number of breath-holds to image the heart. Single-shot phase-sensitive inversion-recovery (PSIR) true-FISP may be combined with parallel imaging using SENSE to achieve high spatial resolution. SNR may be im...

متن کامل

Quantification of myocardial late gadolinium enhancement using synthetic inversion recovery imaging

Background Inversion recovery (IR) late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) is generally used for post-contrast infarct detection in the myocardium. Novel technological advancements allow for the generation of synthetic IR images based on the pixel-bypixel T1 values. Theoretically, synthetic IR images can be retrospectively generated at any inversion time (TI). In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2006