In vitro alternatives for ocular irritation.

نویسندگان

  • R D Curren
  • J W Harbell
چکیده

The necessity of using animals to test whether new chemicals and products are eye irritants has been questioned with increasing frequency and fervor over the last 20 years. During this time many new nonanimal methods have been proposed as reliable alternatives to the traditional rabbit (Draize) test. To date, however, none of these nonanimal (in vitro) tests have become universally accepted as a complete replacement for the Draize test. To understand why a complete replacement has not been found, one has to first understand the reasonably complex structure of the eye, the standard Draize scoring scale--which is based on a qualitative evaluation of three different tissues--the differences between human and rabbit eyes, the intrinsic variability of the animal test, and the details of the different in vitro tests that have been proposed as replacements. The in vitro tests vary from relatively simple assays using single cells to more sophisticated assays that use discarded animal tissue or artificially constructed human tissue. It is clear that appropriately designed in vitro tests will eventually give more useful mechanistic information about ocular injury from which we can more comfortably predict the risk of human eye irritation from new products and ingredients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alternatives to In Vivo Draize Rabbit Eye and Skin Irritation Tests with a Focus on 3D Reconstructed Human Cornea-Like Epithelium and Epidermis Models

Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 4...

متن کامل

The bovine corneal opacity and permeability test in routine ocular irritation testing and its improvement within the limits of OECD test guideline 437.

Data on eye irritation are generally needed for the hazard identification of chemicals. As the Bovine Corneal Opacity and Permeability (BCOP) test has been accepted by many regulatory agencies for the identification of corrosive and severe ocular irritants since September 2009 (OECD Test Guideline 437, TG 437), we evaluated this alternative method for routine testing at BASF. We demonstrated ou...

متن کامل

Formulation and evaluation of Moxifloxacin hydrochloride ocular nanoparticles

The objective of the present study was to prepare controlled release formulation of Moxifloxacin hydrochloride ocular nanoparticles. The nanoparticles were prepared by solvent displacement method using Eudragit RL 100 as a polymer. Different formulations were prepared by varying the ratios of drug and polymer and varying the ratios of organic and aqueous phase. The formulations were evaluated i...

متن کامل

Formulation and evaluation of Moxifloxacin hydrochloride ocular nanoparticles

The objective of the present study was to prepare controlled release formulation of Moxifloxacin hydrochloride ocular nanoparticles. The nanoparticles were prepared by solvent displacement method using Eudragit RL 100 as a polymer. Different formulations were prepared by varying the ratios of drug and polymer and varying the ratios of organic and aqueous phase. The formulations were evaluated i...

متن کامل

Development of the EpiOcular(TM) eye irritation test for hazard identification and labelling of eye irritating chemicals in response to the requirements of the EU cosmetics directive and REACH legislation.

The recently implemented 7th Amendment to the EU Cosmetics Directive and the EU REACH legislation have heightened the need for in vitro ocular test methods. To address this need, the EpiOcular(TM) eye irritation test (EpiOcular-EIT), which utilises the normal (non-transformed) human cell-based EpiOcular tissue model, has been developed. The EpiOcular-EIT prediction model is based on an initial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 106  شماره 

صفحات  -

تاریخ انتشار 1998