Advantages and challenges with using hypoxic air venting as fire protection
نویسندگان
چکیده
The use of hypoxic air venting system as fire protection is increasing and is sometimes used to replace traditional extinguishing systems. An oxygen level of 15% is generally used because a lower concentration could pose serious health risks. On the request of the Swedish Radiation Safety Authority, a literature review was conducted to determine advantages and challenges with the system and further research needs. The main advantages with a reduced oxygen environment are the reduced probability of ignition and lowered heat release rate. However, at 15% oxygen level, risk for fire still exists, and the system cannot be seen as an alternative to extinguishing systems. Reduced oxygen environment also results in higher production rates of soot and smoke, and there is limited knowledge regarding the effect of fuel configuration and fire behavior of products. In addition, a first evaluation of the test method specified in the hypoxic air venting standards was carried out through testing. The testing showed that the particleboard passed the test criteria at normal atmosphere even though it is commonly known that a particleboard burns in normal air. It is concluded that the test method has deficiencies, and there is clearly a need for development of the test method to guarantee safety levels. © 2013 The Authors. Fire and Materials published by John Wiley & Sons, Ltd. Received 12 April 2013; Revised 19 June 2013; Accepted 26 June 2013
منابع مشابه
Determining Factors Affecting Fire Risk in a Hospital in Qazvin, Iran
Background: Hospitals are highly vulnerable to fire because of the presence of vulnerable people (patients, medical staff, and visitors), expensive equipment, and the ignorance and low-risk perception of occupants. Injuries caused by fire can result in life and financial losses and can disrupt the performance of a hospital. Fire risk assessment is an effective way to assess vulnerability, capac...
متن کاملEffect of Radiation Heat Loss and Ventilation on Dust Explosions in Spherical Vessels
The flame propagation through a coal dust-air mixture in a spherical vessel was studied by means of a one-dimensional, Arrhenius-type kinetics and quasi-steady model. The model includes the evaporation of the volatile matter of dust particles into a known gaseous fuel (methane) and the single-stage reaction of the gas-phase combustion. Effect of venting devices as safety idea and the radiation ...
متن کاملAnalysis of the Thermal Comfort Properties and Heat Protection Performance of Cotton/Nylon-Kermel Fabrics
In this research, fire and radiant heat protection and thermal comfort properties of cotton/nylon-Kermel blended woven fabrics, were utilized to predict the thermal comfort and protection limit of this fabric structure based on Woo and Barker developed model. The results showed that the porosity, the air permeability and the thermal resistance increased with Kermel fiber blend ratio. Conversely...
متن کاملIdentification and prioritization of effective factors in fire incidents preparation programs
One of the major challenges in mega cities is the degree of the preparedness of organizations, institutions and people in facing with critical conditions and their immediate reaction according to pre-defined instructions. Identification of priorities and acting accordingly is an undeniable factor in urban crisis management. The purpose of this research was to identify the priorities of prepared...
متن کاملVapor-venting, Micromachined Heat Exchanger for Electronics Cooling
The increasing complexity of modern integrated circuits and need for high-heat flux removal with low junction temperatures motivates research in a wide variety of cooling and refrigeration technologies. Two-phase liquid cooling is especially attractive due to high efficiency and low thermal resistances. While two-phase microfluidic cooling offers important benefits in required flow rate and pum...
متن کامل