Analysis of genetic variability within the immunodominant epitopes of envelope gp41 from human immunodeficiency virus type 1 (HIV-1) group M and its impact on HIV-1 antibody detection.

نویسندگان

  • J Dorn
  • S Masciotra
  • C Yang
  • R Downing
  • B Biryahwaho
  • T D Mastro
  • J Nkengasong
  • D Pieniazek
  • M A Rayfield
  • D J Hu
  • R B Lal
چکیده

The serodiagnosis of human immunodeficiency virus type 1 (HIV-1) infection primarily relies on the detection of antibodies, most of which are directed against the immunodominant regions (IDR) of HIV-1 structural proteins. Among these, the N-terminal region of gp41 contains cluster I (amino acids [aa] 580 to 623), comprising the cytotoxic T-lymphocyte epitope (AVERYLKDQQLL) and the cysteine loop (CSGKLIC), and cluster II (aa 646 to 682), comprising an ectodomain region (ELDKWA). To delineate the epitope diversity within clusters I and II and to determine whether the diversity affects serologic detection by U.S. Food and Drug Administration (FDA)-licensed enzyme immunoassay (EIA) kits, gp41 Env sequences from 247 seropositive persons infected with HIV-1 group M, subtypes A (n = 42), B (n = 62), B' (n = 13), C (n = 38), D (n = 41), E (n = 18), F (n = 27), and G (n = 6), and 6 HIV-1-infected but persistently seronegative (HIPS) persons were analyzed. While all IDR were highly conserved among both seropositive and HIPS persons, minor amino acid substitutions (<20% for any one residue, mostly conservative) were observed for all subtypes, except for B', in comparison with the consensus sequence for each subtype. Most importantly, none of the observed substitutions among the group M plasma specimens affected antibody detection, since all specimens (n = 152) tested positive with all five FDA-licensed EIA kits. Furthermore, all specimens reacted with a group M consensus gp41 peptide (WGIKQLQARVLAVERYLKDQQLLGIWGCSGKLICTTAVPWNASW), and high degrees of cross-reactivity (>80%) were observed with an HIV-1 group N peptide, an HIV-1 group O peptide, and a peptide derived from the homologous region of gp41 from simian immunodeficiency virus from chimpanzee (SIVcpz). Taken together, these data indicate that the minor substitutions observed within the IDR of gp41 of HIV-1 group M subtypes do not affect antibody recognition and that all HIV-1-seropositive specimens containing the observed substitutions react with the FDA-licensed EIA kits regardless of viral genotype and geographic origin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study

Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...

متن کامل

Conserved and exposed epitopes on intact, native, primary human immunodeficiency virus type 1 virions of group M.

We have examined the exposure and conservation of antigenic epitopes on the surface envelope glycoproteins (gp120 and gp41) of 26 intact, native, primary human immunodeficiency virus type 1 (HIV-1) group M virions of clades A to H. For this, 47 monoclonal antibodies (MAbs) derived from HIV-1-infected patients were used which were directed at epitopes of gp120 (specifically V2, C2, V3, the CD4-b...

متن کامل

Vertical transmission of human immunodeficiency virus type 1: seroreactivity by maternal antibodies to the carboxy region of the gp41 envelope glycoprotein.

Maternal antibodies against the envelope glycoprotein of human immunodeficiency virus type 1 (HIV-1) have previously been suggested to be important in influencing the rate of vertical transmission. In this study, serum antibody responses in mothers who did or did not transmit HIV-1 infection to their children were measured against the carboxy region of the transmembrane envelope glycoprotein gp...

متن کامل

A recombinant human immunodeficiency virus type 1 envelope glycoprotein complex stabilized by an intermolecular disulfide bond between the gp120 and gp41 subunits is an antigenic mimic of the trimeric virion-associated structure.

The few antibodies that can potently neutralize human immunodeficiency virus type 1 (HIV-1) recognize the limited number of envelope glycoprotein epitopes exposed on infectious virions. These native envelope glycoprotein complexes comprise three gp120 subunits noncovalently and weakly associated with three gp41 moieties. The individual subunits induce neutralizing antibodies inefficiently but r...

متن کامل

Epitope Specificity of Human Immunodeficiency Virus-1 Antibody Dependent Cellular Cytotoxicity [ADCC] Responses

Antibody dependent cellular cytotoxicity [ADCC] has been suggested to play an important role in control of Human Immunodeficiency Virus-1 [HIV-1] viral load and protection from infection. ADCC antibody responses have been mapped to multiple linear and conformational epitopes within the HIV-1 envelope glycoproteins gp120 and gp41. Many epitopes targeted by antibodies that mediate ADCC overlap wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2000