Late Disassembly of Femoral Head and Neck of A Modular Primary Total Hip Arthroplasty

نویسندگان

  • Parvej Ahmed
  • Dinesh Kumar
چکیده

INTRODUCTION Modular total hip arthroplasty system are now widely used, as these components increase the flexibility during primary and revision total hip arthoplasty. But this modularity itself associated with some risk of intraoperative and postoperative complications. CASE REPORT We report a case of late disassembly of a primary total arthroplasty in a 42 years old patient five years after the replacement surgery where the femoral head remained in the acetabular socket. CONCLUSION Femoral head should be solidly impacted onto the stem and confirm that it has been assembled correctly before reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Combined bilateral femoral head necrosis and pertrochanteric fracture: a case report

INTRODUCTION Modular femoral implants have become a regular feature of revision hip surgery. However, for a primary hip arthroplasty, such as a femoral neck fracture case, the implant of choice is a standard femoral component, while compelling literature evidence have made osteosynthesis the standard procedure for the vast majority of trochanteric fractures. CASE PRESENTATION We present the c...

متن کامل

Result of Modular Necks in Primary Total Hip Arthroplasty with a Average Follow-up of Four Years

PURPOSE This study aimed to investigate the outcomes of modular neck-utilization in primary total hip arthroplasty (THA). MATERIALS AND METHODS Thirty patients (34 hips) who had modular stem THA between April 2011 and January 2013 were evaluated. There were 19 men and 11 women with a mean age of 61.2 years at the time of surgery. There were 20 cases of osteonecrosis of femoral head, 7 cases o...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Fracture of the Modular Neck in Total Hip Arthroplasty

Modularity of the components in total hip arthroplasty has had an increase in popularity in the last decades. We present the case of a 53-year-old man with a history of avascular necrosis of the femoral head due to a hypophyseal adenoma. A total hip modular arthroplasty was implanted. Three and a half years after the surgery the patient attended the emergency room due to acute left hip pain wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015