Effect of Bed Length and Vapor Maldistribution on Structured Packing Performance

نویسنده

  • Tony J. Cai
چکیده

Recent tests of a 250 m/m structured packing in a 1.22 m diameter column have produced some unanticipated results. Using two quite different systems, mass transfer performance in a relatively short 1.69 m bed was significantly better than previous results in a longer 3.78 m bed. No bed length effect was found on pressure drop. Two different severe vapor maldistributions were studied using a vacuum system with the 1.69 m bed. No significant effect of vapor maldistribution on mass transfer efficiency, capacity and pressure drop was observed. The HETP “hump”, or deterioration of mass transfer performance, previously reported in a 3.78 m bed was again found in the short bed using 11.4 bar butane. However, tests with a 133 m/m packing did not show the hump in a 3.81 m bed. The experimental results are compared to predictions from various literature models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the Initial Gas Maldistribution on the Pressure Drop of Structured Packings

This paper presents results of a comprehensive, large scale experimental study devoted to establishing the relation between the quality of initial gas (mal)distribution, as created by common liquid collecting devices used in redistribution sections of packed columns, and the hydraulics of a structured packing bed. Both dry and wet bed experiments were conducted with air/water system under ambie...

متن کامل

Modeling of Mixture Separation in a Column with Structured Packing. Effects of Liquid Maldistribution

INTRODUCTION. What is the effect of maldistribution on the mass transfer efficiency of a distillation column containing structured packing?. The column of structured packing is considered to consist of a set of unit cells. Each pair of sheets gives a two-dimensional set of " elementary " cells:

متن کامل

The Effect of Maldistribution on Separation in Packed Distillation Columns

For a packed bed in a distillation column, fmax is the maximum fractional liquid maldistribution that can be tolerated in a parallel column model whilst still being able to achieve the design separation. It was previously shown that fmax can be easily calculated from a conventional column simulation output and it is a measure of the sensitivity of a packed bed to maldistribution. In this paper,...

متن کامل

CFD Simulation of Parameters Affecting Hydrodynamics of Packed Beds: Effects of Particle Shape, Bed Size, and Bed Length

Packed bed reactors have many applications in different industries such as chemical, petrochemical, and refinery industries. In this work, the effects of some parameters such as the shape and size of particles, bed size, and bed length on the hydrodynamics of the packed beds containing three spherical, cylindrical, and cubic particles types are investigated using CFD. The effect of the combinat...

متن کامل

Mass transfer performance of modular catalytic structured packing

A mechanistic, parallel channel model was developed and validated experimentally to enable the prediction of mass transfer performance of the Katapak-SP, a novel, modular catalytic structured packing. Total reflux distillation experiments were carried out at atmospheric pressure in a column with internal diameter of 0.45 m, using aqueous (Methanol/Water) and organic (Cyclohexane/n-Heptane) test...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002