The diagnostic value of adenosine stress-contrast echocardiography for diagnosis of coronary artery disease in hypertensive patients: comparison to Tl-201 single-photon emission computed tomography.
نویسندگان
چکیده
BACKGROUND The use of the vasodilating agent adenosine as stressor in conjunction with myocardial contrast echocardiography has not been extensively evaluated in hypertensive patients. Our aim was to evaluate the diagnostic value of adenosine myocardial contrast echocardiography (MCE) in comparison to single-photon emission computed tomography (SPECT), with reference to angiographic findings, in a hypertensive population. METHODS Fifty hypertensive subjects, treated with standard antihypertensive treatment, were submitted to adenosine stress MCE, adenosine SPECT, and coronary angiography within a 1-month period, without any intervening events. RESULTS Sensitivity, specificity, and accuracy were 88%, 89%, 88% for MCE and 80%, 94%, 85% for SPECT, respectively (P = not significant). In the analysis by coronary territory, it appears that MCE and SPECT are both more accurate in detecting lesions of the anterior than of the posterior coronary system, as suggested by the good concordance to angiography results in the left anterior descending artery territory (k = 0.640 and 0.671, respectively). Agreement with angiographic findings was moderate for the right coronary artery (k = 0.561 and 0.539, respectively), whereas left circumflex artery lesions were more accurately detected by MCE than by SPECT (k = 0.533 and 0.400, respectively), that is, MCE appears to be superior in the left circumflex artery territory. CONCLUSIONS In hypertensive patients, adenosine MCE has similar overall diagnostic accuracy with SPECT for assessment of coronary artery disease but is superior in the left circumflex artery territory.
منابع مشابه
Physiologic Assessment of Coronary Artery Stenosis by Coronary Flow Reserve Measurements With Transthoracic Doppler Echocardiography: Comparison With Exercise Thallium-201 Single-Photon Emission Computed Tomography
OBJECTIVES We evaluated the value of coronary flow reserve (CFR), as determined by transthoracic Doppler echocardiography (TTDE), for physiologic assessment of coronary artery stenosis severity, and we compared TTDE measurements with those obtained by exercise thallium201 (Tl-201) single-photon emission computed tomography (SPECT). BACKGROUND Coronary flow reserve measurements by TTDE have been...
متن کاملComparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease.
The diagnostic performance of rubidium-82 (Rb-82) positron emission tomography (PET) and thallium-201 (Tl-201) single-photon emission-computed tomography (SPECT) for detecting coronary artery disease was investigated in 81 patients (52 men, 29 women). PET studies using 60 mCi of Rb-82 were performed at baseline and after intravenous infusion of 0.56 mg/kg dipyridamole in conjunction with handgr...
متن کاملImproved diagnostic performance of thallium-201 myocardial perfusion scintigraphy in coronary artery disease: from planar to single photon emission computed tomography imaging.
BACKGROUND This study was performed to compare Tl-201 myocardial perfusion single photon emission computed tomography (SPECT) with planar scintigraphy in the diagnosis of coronary artery disease (CAD). METHODS Retrospectively, 240 of 3262 patients, with exercise-redistribution Tl-201 myocardial perfusion scintigraphy performed between January 1990 and October 1997, were analyzed to compare Tl...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملPrognostic Value of Functional Variables as Assessed by Gated Thallium-201 Myocardial Perfusion Single Photon Emission Computed Tomography for Major Adverse Cardiac Events in Patients with Coronary Artery Disease.
PURPOSE Gated single photon emission computed tomography (SPECT) using thallium-201 (Tl-201) has the capacity to evaluate the earlier post-stress (PS) function compared to technetium-99m labeled tracers, and may be more sensitive in detecting transient ventricular dysfunction caused by stress-induced ischemia. The purpose of this study was to assess the prognostic value of functional variables ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of hypertension
دوره 20 5 شماره
صفحات -
تاریخ انتشار 2007