Effective inspired oxygen concentration measured via transtracheal and oral gas analysis.

نویسندگان

  • Gerald H Markovitz
  • James Colthurst
  • Thomas W Storer
  • Christopher B Cooper
چکیده

BACKGROUND The fraction of inspired oxygen (F(IO(2))) is quoted for different oxygen delivery systems, but variations in inspiratory flow and tidal volume make precise measurement difficult. We developed a reliable method of measuring the effective F(IO(2)) in patients receiving supplemental oxygen. METHODS Ten subjects with chronic hypoxemia breathed through a mouthpiece with a sampling probe connected to a mass spectrometer. Four of the 10 subjects had transtracheal catheters that allowed direct sampling of tracheal gas. We used oxygen concentrations of 47% and 97%, and flow rates between 1 L/min and 8 L/min. We also compared oxygen delivery via nasal cannula and transtracheal catheter. Effective F(IO(2)) was derived from plots of the fractional concentrations of carbon dioxide versus oxygen. RESULTS We found excellent correlation between the effective F(IO(2)) values from tracheal and oral sampling (r = 0.960, P < .001). With 97% oxygen via nasal cannula, effective F(IO(2)) increased by 2.5% per liter of increased flow (P < .001); effective F(IO(2)) reached 32.7% at 5 L/min while P(aO(2)) increased by 12 mm Hg per liter of increased flow. In 4 subjects with a transtracheal catheter, effective F(IO(2)) increased 5.0% (P < .001) per liter of increased flow, and P(aO(2)) increased by 13 mm Hg per liter of increased flow, whereas in the same 4 subjects using nasal cannula for oxygen delivery, P(aO(2)) increased by only 6 mm Hg per liter of increased flow. CONCLUSIONS Exhaled gas sampled at the mouth accurately reflected the effective F(IO(2)) in the trachea. In relation to inspired oxygen flow, the effective F(IO(2)) was lower than is conventionally thought. Compared to nasal cannula, transtracheal catheter approximately doubled the effective F(IO(2)) at a given flow rate. Accurate knowledge of F(IO(2)) should aid clinicians in managing patients with acute and chronic lung diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inspired oxygen concentrations in semiclosed circle absorber circuits with low flows of nitrous oxide and oxygen.

Fresh gas flows of 1-5 l./min containing oxygen concentrations of 25-50% in nitrous oxide were led into a semiclosed circle absorber circuit. The resulting inspired oxygen concentrations were measured under conditions of spontaneous respiration. The lower the fresh gas flow, the greater was the discrepancy between fresh gas and inspired oxygen concentration. No association between minute volume...

متن کامل

Tracheal gas insufflation and related techniques to introduce gas flow into the trachea.

Over the past 50 years, a variety of techniques have been developed that have in common the insufflation of gas into the central airway to facilitate carbon dioxide (CO2) clearance. These include continuous insufflation of oxygen, transtracheal jet ventilation, high frequency jet ventilation, transtracheal oxygen administration, intratracheal pulmonary ventilation, and tracheal gas insufflation...

متن کامل

Aprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery

 Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...

متن کامل

Oxygen and acid-base parameters

A complete pH and blood gas analysis of arterial and mixed venous blood may comprise more than forty different quantities. We have selected sixteen, including patient temperature. The arterial oxygen tension group includes the oxygen tension, fraction of oxygen in inspired air, and fraction of mixed venous blood in the arterial (total physiological veno-arterial shunting). The haemoglobin oxyge...

متن کامل

Aprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery

Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery were prospect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2010