In-vivo study of osseointegration in Prestige LP cervical disc prosthesis
نویسندگان
چکیده
BACKGROUND A study was designed to quantify the extent of porous osseointegration at the prosthesis-bone interface in the Prestige LP prosthesis containing a plasma-sprayed titanium coating. METHODS Using an anterior surgical approach, cervical disc arthroplasty was performed in 8 mature male goats at the C3-C4 segment, followed by implantation of the Prestige LP prosthesis. The vertebral specimens were examined using microcomputed tomograph for histomorphometric quantification, and proceeded by routine paraffin processing for histological observation. Hence, the porous osseointegration at the prosthesis-bone interface was evaluated based on histologic and histomorphometric analyses. RESULTS At 6 months after surgery, there was no evidence of prosthesis migration, loosening, subsidence, or neurologic or vascular complications. Based on gross histologic analysis, there was excellent porous ingrowth at the prosthesis-bone interface, without significant histopathologic changes. Histomorphometric analysis at the prosthesis-bone interface indicated the mean porous ingrowth of 48.5% ± 10.4% and the total ingrowth range of 36.6 to 59.8%. CONCLUSIONS As the first comprehensive in vivo investigation into the Prestige LP prosthesis, this project established a successful animal model in the evaluation of cervical disc arthroplasty. Moreover, histomorphometric analysis of porous ingrowth at the prosthesis-bone interface was more favorable for cervical disc arthroplasty with the Prestige LP prosthesis compared to historical reports of appendicular total joint arthroplasty.
منابع مشابه
Biomechanical Analysis of a Novel Prosthesis Based on the Physiological Curvature of Endplate for Cervical Disc Replacement
STUDY DESIGN Biomechanical analysis of a novel prosthesis based on the physiological curvature of endplate was performed. OBJECTIVE To compare the biomechanical differences between a novel prosthesis based on the physiological curvature of the endplate and the Prestige LP prosthesis after cervical disc replacement (CDR). SUMMARY OF BACKGROUND DATA Artificial disc prostheses have been widely...
متن کاملBiomechanical evaluation of cervical disc replacement with a novel prosthesis based on the physiological curvature of endplate
BACKGROUND Most of the current available cervical disc prostheses present a flat surface instead of an arcuate surface which is most similar to the morphology of cervical endplate. Therefore, we designed a novel prosthesis (Pretic-I, Trauson) based on the physiological curvature of the cervical endplate. Biomechanical evaluation of cervical disc replacement (CDR) with this novel prosthesis was ...
متن کاملCervical Footprint Anthropometry in Indian Population: Implications on Design of Artificial Disc Replacement Devices.
STUDY DESIGN Cross-sectional study. PURPOSE To accurately measure the dimensions of cervical endplates based on computed tomography (CT) scans in Indian population and assess accuracy of match with currently available cervical disc prostheses. OVERVIEW OF LITERATURE The dimensions of currently available cervical disc replacement implants are based on early published geometrical measurements...
متن کاملFootprint Mismatch of Cervical Disc Prostheses with Chinese Cervical Anatomic Dimensions
BACKGROUND The footprint of most prostheses is designed according to Caucasian data. Total disc replacement (TDR) has been performed widely for cervical degenerative diseases in China. It is essential to analyze the match sizes of prostheses footprints and Chinese cervical anatomic dimensions in our study. METHODS The anatomic dimensions of the C4-C7 segments of 138 patients (age range 16-77 ...
متن کاملStress Analyses of Load Sharing on Facet and Uncovertebral Joints with Bryan, Prestige LP, and Prodisc-C Cervical Disc Prostheses
INTRODUCTION Artificial disc arthroplasty, as a promising treatment for disc degenerative diseases, has been reported to restore normal disc height, preserve segmental motion and decrease adjacent level degeneration. Despite its encouraging short term outcomes, complications related to device and surgical procedure such as subsidence, dislocation and instability due to misalignment warrant furt...
متن کامل