Tidal breath analysis for infant pulmonary function testing. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/American Thoracic Society.

نویسندگان

  • J H Bates
  • G Schmalisch
  • D Filbrun
  • J Stocks
چکیده

The aim of this position paper is to provide recommendations pertaining to software and equipment requirements when analysing tidal breathing measurements in infants. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis, and reporting of results, and highlight areas in which further research is needed before consensus can be reached. When collecting tidal breathing data in infants and children, equipment dead space and resistance must be minimized, all sources of leak eliminated, and a flowmeter with appropriate frequency response and linearity employed. Inspired gases should be corrected to body temperature, barometric pressure and saturated with water vapour conditions and efforts made to eliminate the various sources of drift in volume that can occur. In addition, the analogue-to-digital converter used to sample data must be capable of adequately resolving the highest and lowest flows required by the study. An adequate sampling rate must be used; 50-100 Hz may be sufficient for the determination of timing and volume parameters, especially in older infants, but rates of 200 Hz are recommended for analysis of the tidal breathing flow/volume loop and other sensitive parameters such as time to peak tidal expiratory flow/expiratory time. The potentially most troublesome aspect of tidal breath analysis from the computational point of view is the identification of the beginning and end of inspiration and expiration. Once methods and equipment for the measurement and analysis of tidal breathing in infants have been standardized, there is an urgent need to establish appropriate reference ranges for various key parameters so that they may be used more effectively in the clinical setting. Implementation of these recommendations should help to ensure that such measurements are as accurate as possible and that more meaningful comparisons can be made between data collected in different centres or with different equipment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The infant lung function model: a mechanical analogue to test infant lung function equipment.

To facilitate international multicentre studies and quality control of infant pulmonary function measurements, the European Respiratory Society-American Thoracic Society (ERS-ATS) working group for infant lung function testing aims to develop specifications for standardized infant lung function equipment and software. However, a standardized test device is also needed to test whether existing i...

متن کامل

[Coming together: the ATS/ERS consensus on clinical pulmonary function testing].

S ince 1979, guidelines for standardising pulmonary function tests have been published and updated by both the American Thoracic Society (ATS) [1–6] and the European Respiratory Society (ERS) [7–9]. In addition, several joint ATS/ERS workshops on pulmonary function testing have been held and the resulting reports published [10, 11]. In 1995, European scientists participated in the ATS updates o...

متن کامل

Respiratory function measurements in infants: symbols, abbreviations and units.

Communication about infant lung function testing, as in any other field of science and medicine, requires the use of symbols, abbreviations, units, prefixes and suffixes. These should be unambiguous, and this is achieved by rigorous standardization by international scientific and medical bodies, and by governments. The present recommendations derive from the report of the European Community for...

متن کامل

ATS/ERS statement: raised volume forced expirations in infants: guidelines for current practice.

Over the past few years, a series of documents (1–8) have been produced by the American Thoracic Society/European Respiratory Society Task Force on Standards for Infant Respiratory Function Tests, and this document represents part of this series. The aim of this task force is to summarize what is currently seen to be good laboratory practice, and to provide recommendations for users and manufac...

متن کامل

Assessment of an infant whole-body plethysmograph using an infant lung function model.

In order to facilitate international multicentre studies and improve the quality control of infant pulmonary function measurements, the European Respiratory Society-American Thoracic Society Task Force for infant lung function testing has recently developed specifications for standardized infant lung function equipment and software. A mechanical infant lung model analogue has been developed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2000