l1-denoised Autocalibrating Parallel Imaging

نویسندگان

  • T. Zhang
  • M. Lustig
  • S. Vasanawala
  • J. M. Pauly
چکیده

Introduction: There has been a rising interest in combining parallel imaging (PI) [1,2] with compressed sensing (CS) [3] to achieve high acceleration and reduce the noise amplification that comes from traditional PI reconstruction (e.g. SENSE[1], GRAPPA[2], etc). Existing approaches are: (a) sequentially apply PI and CS [4]; (b) sequentially apply CS and PI [5]; (c) simultaneously apply PI and CS [6-8]. However, noise correlation introduced by autocalibrating PI reconstruction has not been utilized before. In this work, we present a novel sequential approach that consists in first applying GRAPPA followed by CS. We use the fact that a noise covariance matrix of the GRAPPA reconstruction can be constructed from the GRAPPA interpolation kernels. The covariance matrix is used to “intelligently inform” the CS optimization about the confidence levels of the PI reconstruction entries. This results in better CS reconstruction that efficiently suppresses noise and provides high image quality. Theory and Method: As shown in Fig. 1, after GRAPPA data synthesis, reconstructed entries are correlated. In presence of noise, the synthesized value for each point and its variance tell us the range of the true value of the point; the covariance matrix tells how the noise is correlated. With this knowledge, CS optimization can then suppress the noise according to its underlying correlation. Let y be the entire acquired k-space grid data for all coils, xi be the entire k-space grid data for the ith coil, and Gi be the GRAPPA interpolation matrix for the ith coil. Data synthesis can then be written as: xi = Gi y. For simplicity, assume the noise for the acquired data is independently identically distributed (i.i.d.) Gaussian noise with variance σ (the actual noise correlation of the acquired data could be obtained with an extra scan). Post synthesis, the covariance matrix of the noise Σi for the ith coil is: Σi = σGiGi . Equipped with this information, we perform a modified CS optimization. Joint sparsity is used as the objective function [5,6,10]: minimize Σr(Σi||wi(r)||), subject to ||Σi(xi -xi)||2 <ε, wi=ψFxi , i=1, ... n, where xi is the GRAPPA reconstruction result, xi is the actual k-space data, F is a Fourier transform operator, and ψ is a sparsifying transform operator. It is difficult to calculate the inversion of Σi directly. Instead, we approximate the inversion of Σi iteratively while calculating the nonlinear conjugate gradient of the objective function [3]. Furthermore, approximation of Σi (e.g., only considering the variance) can also save computation cost. Individual coil images are combined using sum-of-squares. Results: A phantom simulation was performed to demonstrate the proposed method (Fig. 2). Eight-channel Shepp-Logan phantom data set (image size: 128x128) was generated with i.i.d Gaussian noise added separately into each image (SNR=50). Jittered sampling [9] with 2x2 (ky x kz) undersampling and autocalibrating signals 20x20 was applied. GRAPPA reconstruction was performed with interpolation kernel size 7x7. Total variation (TV) penalty was used for l1 constraints. Similar reconstruction results were achieved by only considering the variance information. However, reconstruction was less accurate when no covariance information was used. Simulation with similar parameters as in the phantom experiment was performed on an 8-channel 3D extremity exam acquired on a 1.5T GE Signa Excite scanner. Reconstruction results of GRAPPA and proposed method with wavelet and TV penalties are shown in Fig. 3. As can be seen, the proposed method efficiently reduced the noise that was amplified during GRAPPA data synthesis. Conclusion: The proposed method sequentially applies GRAPPA and CS. Using the noise correlation obtained during GRAPPA data synthesis, l1-denoising can efficiently suppress noise according to its correlation and improve image quality. Using only variance information achieves similar reconstruction quality and further reduces computation cost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear Inversion with L1-Wavelet Regularization – Application to Autocalibrated Parallel Imaging

To improve parallel imaging techniques with autocalibration, algorithms were recently presented which estimate the coil sensitivities and the image at the same time [1,2]. However, even with perfectly known coil sensitivites parallel imaging suffers from much lower SNR than to be expected from the reduced scan time alone. This is due to the reconstruction process (quantified by the g-factor map...

متن کامل

Optimized parallel imaging for dynamic PC-MRI with multidirectional velocity encoding.

Phase contrast MRI with multidirectional velocity encoding requires multiple acquisitions of the same k-space lines to encode the underlying velocities, which can considerably lengthen the total scan time. To reduce scan time, parallel imaging is often applied. In dynamic phase contrast MRI using standard generalized autocalibrating partially parallel acquisitions (GRAPPA), several central k-sp...

متن کامل

Magnetic Resonance in Medicine 63:502–509 (2010) IIR GRAPPA for Parallel MR Image Reconstruction

Accelerated parallel MRI has advantage in imaging speed, and its image quality has been improved continuously in recent years. This paper introduces a two-dimensional infinite impulse response model of inverse filter to replace the finite impulse response model currently used in generalized autocalibrating partially parallel acquisitions class image reconstruction methods. The infinite impulse ...

متن کامل

Use of Parallel Imaging in Peripheral Contrast-enhanced Magnetic Resonance Angiography: Retrospective Study

Objective: To evaluate the application of a parallel imaging technique — generalised autocalibrating partially parallel acquisition — in peripheral contrast-enhanced magnetic resonance angiography. Patients and Methods: This was a retrospective review of 17 consecutive patients with peripheral vascular disease who underwent lower-extremity 3-dimensional contrast-enhanced magnetic resonance angi...

متن کامل

GRAPPA-based susceptibility-weighted imaging of normal volunteers and patients with brain tumor at 7 T.

Susceptibility-weighted imaging (SWI) is a valuable technique for high-resolution imaging of brain vasculature that greatly benefits from the emergence of higher field strength MR scanners. Autocalibrating partially parallel imaging techniques can be employed to reduce lengthy acquisition times as long as the decrease in signal-to-noise ratio does not significantly affect the contrast between v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009