Water exchange versus carbon dioxide insufflation in unsedated colonoscopy: a multicenter randomized controlled trial.

نویسندگان

  • Kjetil Garborg
  • Michal F Kaminski
  • Wolfgang Lindenburger
  • Håvard Wiig
  • Audun Hasund
  • Ewa Wronska
  • Rolf Bruun Bie
  • Britta Kleist
  • Leif Løvdal
  • Øyvind Holme
  • Mette Kalager
  • Geir Hoff
  • Michael Bretthauer
چکیده

BACKGROUND AND STUDY AIMS Compared with air insufflation, water exchange and carbon dioxide (CO2) insufflation have been shown to reduce colonoscopy discomfort; however, head-to-head studies of the two methods are lacking. We aimed to compare water exchange and CO2 insufflation directly with regard to pain during primary unsedated colonoscopy. METHODS Patients willing to undergo unsedated colonoscopy at three centers in Norway and Poland were randomized 1:1 to water exchange or CO2 insufflation during colonoscope insertion. Patients were blinded to group allocation. The primary end point was the proportion of patients reporting moderate or severe procedural pain on a 4-point verbal rating scale (VRS-4) at discharge. Secondary outcomes included the proportion of patients reporting no pain on the VRS-4. RESULTS A total of 473 patients were randomized. A discharge pain questionnaire was completed by 226 of 234 patients (97 %) in the water exchange group versus 226 of 239 patients (95 %) in the CO2 group (P = 0.37). Moderate or severe pain was reported by 47 of 226 patients (21 %) in the water exchange group versus 60 of 226 patients (27 %) in the CO2 group (P = 0.15). No pain was reported by 100 of 226 patients (44 %) and 69 of 226 patients (31 %) in the water exchange and CO2 groups, respectively (P = 0.003). On-demand sedation was used in 15 patients (6 %) in each group (P = 0.95). CONCLUSIONS There was no significant reduction in moderate or severe pain in a comparison of water exchange with CO2 insufflation. The secondary outcome of no pain was significantly more frequent in the water exchange group. Clinical trials registry number: NCT01633333.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unsedated Colonoscopy and the Water Method for Minimizing Discomfort in the Unsedated Patients

󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏󰠏 A decade ago, failure of cecal intubation due to pain in ~20% of scheduled unsedated patients in the author’s veterans practice prompted the search for a less uncomfortable approach. Methods that minimized discomfort or enhance cecal intubation included use of pediatric, variable stiffness, comp...

متن کامل

Carbon dioxide insufflation during screening unsedated colonoscopy: a randomised clinical trial

One of the methods used to reduce pain and discomfort during colonoscopy is insufflation of carbon dioxide instead of air. However, the actual benefit of carbon dioxide insufflation is not unequivocally proven. The aim of the study was to evaluate the advantages of carbon dioxide insufflation during screening colonoscopy. A total of 200 patients undergoing screening colonoscopy between 2010 and...

متن کامل

NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy.

BACKGROUND To eliminate the risk of combustion during electrosurgical procedures and to reduce patient discomfort, carbon dioxide (CO2) insufflation has been recommended during colonoscopy. However, air insufflation is still the standard method, perhaps due to the lack of suitable equipment and shortage of randomised studies. AIMS This randomised controlled trial was conducted to assess patie...

متن کامل

Use of warm carbon dioxide insufflators does not affect intra-colonic gas temperature and has no effect on polyp detection rate during colonoscopy – a randomized controlled trial

BACKGROUND AND STUDY AIMS  Methods to improve polyp detection during colonoscopy have been investigated, with conflicting results for warm water irrigation. Carbon Dioxide (CO 2) warmed to 37 °C may have similar or more pronounced effects on bowel motility. This study aimed to assess whether warmed CO 2 would improve polyp detection compared to room temperature air insufflation. PATIENTS AND ...

متن کامل

Water exchange enhanced cecal intubation in potentially difficult colonoscopy. Unsedated patients with prior abdominal or pelvic surgery: a prospective, randomized, controlled trial.

BACKGROUND Colonoscopy is widely used for management of colorectal diseases. A history of abdominal or pelvic surgery is a well-recognized factor associated with difficult colonoscopy. Although water exchange colonoscopy (WEC) was effective in small groups of male U.S. veterans with such a history, its application in other cultural settings is uncertain. OBJECTIVE To investigate the applicati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2015