Low-Load Vickers Microindentation Hardness Testing
نویسندگان
چکیده
ADVANCED MATERIALS & PROCESSES • APRIL 2012 I n 1925 in the UK, Smith and Sandland developed an indentation test that used a squarebased pyramidal-shaped indenter made of diamond[1]. The test was developed because the Brinell test (introduced in 1900), which (until recently) used a round hardened steel ball indenter, could not test steels harder than ~450 HB (~48 HRC). They chose this shape with an angle of 136° between opposite faces to obtain hardness numbers that would be as close as possible to Brinell hardness numbers for the same specimens over the usable Brinell range. This made the Vickers test easy to adopt, and it rapidly gained acceptance. The Vickers test has the great advantage of one hardness scale being used to test all materials, unlike the 30 different Rockwell test scales, each yielding numbers between ~20 and ~100. In the Vickers test, the force is applied smoothly, without impact, and held in contact for 10 to 15 seconds. The force must be controlled precisely. After removing the force, both diagonals are measured and the average is used to calculate the HV according to (for loads £1 kgf):
منابع مشابه
Tungsten tetraboride, an inexpensive superhard material.
Tungsten tetraboride (WB(4)) is an interesting candidate as a less expensive member of the growing group of superhard transition metal borides. WB(4) was successfully synthesized by arc melting from the elements. Characterization using powder X-ray diffraction (XRD) and energy-dispersive X-ray spectroscopy (EDX) indicates that the as-synthesized material is phase pure. The zero-pressure bulk mo...
متن کاملFabrication and Characterization of a Low Magnetic Zr-1Mo Alloy by Powder Bed Fusion Using a Fiber Laser
A low magnetic Zr-1Mo alloy was fabricated by a powder bed fusion (PBF) process using a fiber laser. The microstructure, surface morphology, and pore distribution of the as-built Zr-1Mo alloy were observed. Its magnetic susceptibility and Vickers hardness were evaluated by magnetic susceptibility balance and a microindentation tester, respectively. The as-built Zr-1Mo alloy mainly consisted of ...
متن کاملEffect of Loading Rate Upon Conventional Ceramic Microindentation Hardness
The world standards for conventional ceramic hardness have varying requirements for control of loading rate during the indentation cycle. A literature review suggests that loading rate may affect measured hardness in some instances. In view of the uncertainty over this issue, new experiments over a range of indentation loading rates were performed on a steel, sintered silicon carbide, and an al...
متن کاملAccuracy of Standard Blocks for Hardness and Uncertainty of Hardness
− The authors numerically discuss the accuracy of the hardness values of standard hardness blocks by evaluating the uniformity of hardness blocks and the resolution of hardness values according to test method. As a result of reviewing the results of this evaluation and the reasonability of the currently proposed method for evaluating the uncertainty of hardness values, it is revealed that the v...
متن کاملEffect of QMix 2 in 1, BioPure MTAD and 17% Ethylenediaminetetraacetic Acid on Microhardness of Root Canal Dentin
Aim: To compare the effect of QMix, a mixture of tetracycline, citric acid, and detergent (MTAD), and ethylenediaminetetracetic acid (EDTA) on the microhardness of the root canal dentin. Materials and methods: A total of 30 single-rooted teeth were decoronated at 15 mm from the root apex. Root canal instrumentation using step back technique was done and the specimens were split into two halves ...
متن کامل