Harmonics and Reactive Power Compensation Using Shunt Hybrid Filter
نویسندگان
چکیده
The supply current is distorted by the nonlinear load such UPS, DC drives, AC drives and arc furnace. This current harmonics derates the electrical equipments. Thus the current harmonics are reduced from the supply line using Shunt Hybrid filter. The Hysteresis controller controls the active filter thus the supply current tracks the reference fundamental current extracted by the synchronous reference frame unit. So supply current is free from harmonics and also it provides harmonic compensation. The passive filter is tuned for the dominant harmonic frequency so it reduces the rating of the active filter. The total harmonic distortion and power factor of the supply current of three phase controlled rectifier load with filter and without filter is analyzed using MATLAB simulink and the results are presented.
منابع مشابه
Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure
Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملA New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)
This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
متن کاملPower Quality in Railway Traction and Compensation by Combining Shunt Hybrid Filter and TCR
This paper analyses the quality of electricity in railway traction. Power quality characteristics have been measured as a case study in a traction sub-station in Tamil Nadu, India, where 1400 KVAR capacitor bank is installed. The actual data has been obtained through direct supply of traction load. Harmonics and various power quality problems are generated through the load of current. The emerg...
متن کاملAnn Controller Based Adaptive Shunt Hybrid Filter for Static and Dynamic Loads
Chapter 3 presents ANN based adaptive shunt passive filter, whose performance is found to be superior to fixed element shunt passive filter in harmonic and reactive compensation. However, the drawback is that it can provide only partial harmonic and reactive power compensation. Hence, an ANN based digital controller for active filter is developed. It compensates for the major portion of source ...
متن کامل