In vivo kinematics of a unique posterior-stabilized knee implant during a stepping exercise

نویسندگان

  • Takatomo Mine
  • Kenji Hoshi
  • Kazuyoshi Gamada
  • Koichiro Ihara
  • Hiroyuki Kawamura
  • Ryutaro Kuriyama
  • Ryo Date
چکیده

BACKGROUND Stair-stepping motion is important in daily living, similar to gait. Knee prostheses need to have even more superior performance and stability in stair-stepping motion than in gait. The purpose of this analysis was to estimate in vivo knee motion in stair stepping and determine if this unique knee prosthesis function as designed. METHODS A total of 20 patients with Bi-Surface posterior-stabilizing (PS) implants were assessed. The Bi-Surface PS knee is a posterior-cruciate substitute prosthesis with a unique ball-and-socket joint in the mid-posterior portion of the femoral and tibial components. Patients were examined during stair-stepping motion using a 2-dimensional to 3-dimensional registration technique. RESULTS The kinematic pattern in step up was a medial pivot, in which the level of anteroposterior translation was very small. In step down, the kinematic pattern was neither a pivot shift nor a rollback. From minimum to maximum flexion, anterior femoral translation occurred slightly. CONCLUSIONS In this study, this unique implant had good joint stability during stair stepping. The joint's stability during stair stepping was affected by the design of the femorotibial joint rather than post/cam engagement or the ball-and-socket joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematic analysis of posterior-stabilized total knee arthroplasty during standing up from and sitting down on a chair

BACKGROUND Total knee arthroplasty is effective to regain quality of life. Standing up from and sitting down on a chair and stair stepping motion are important in daily living. We previously reported in vivo kinematics of this implant during a stepping exercise. The purpose of this analysis was to assess in vivo knee motion during standing up from and sitting down on a chair and determine the m...

متن کامل

Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants.

Contemporary posterior cruciate-retaining total knee designs have provided pain relief and improved knee function but have failed to reproduce the kinematics and stability of the normal nonarthritic knee. The Medial Pivot total knee design features a near constant radius of curvature of the femoral component. The tibial surface is highly congruent and asymmetric, permitting a medial pivot motio...

متن کامل

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.

The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant ...

متن کامل

In vivo determination of total knee arthroplasty kinematics: a multicenter analysis of an asymmetrical posterior cruciate retaining total knee arthroplasty.

The objective of this study was to determine if consistent posterior femoral rollback of an asymmetrical posterior cruciate retaining (PCR) total knee arthroplasty was mostly influenced by the implant design, surgical technique, or presence of a well-functioning posterior cruciate ligament (PCL). Three-dimensional femorotibial kinematics was determined for 80 subjects implanted by 3 surgeons, a...

متن کامل

Kinematic analysis of a posterior-stabilized knee prosthesis.

BACKGROUND The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. METHODS Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016