Experimental point spread function of fm pulse imaging scheme.

نویسندگان

  • N A Rao
  • S Mehra
  • J Bridges
  • S Venkatraman
چکیده

In this paper, we have examined the possibility of incorporating pulse compression techniques into a conventional medical B-scan imaging scheme. Linear frequency modulation fm, one form of pulse coding among many others, has been used in this study. With this approach, one can overcome current peak intensity limitations. A theoretical framework that includes medium propagation effects, transducer bandwidth and diffraction effects is presented, which could be used to examine the system point spread function under this imaging scheme. A prototype experimental set-up and signal processing are described and used for simple imaging tasks in attenuating and nonattenuating media. Analysis of the experimental point spread functions shows that resolution similar to conventional short pulse imaging can be achieved. However, the existence of large range side lobe levels usually associated with pulse compression processing can degrade contrast resolution in medical ultrasound. We have considered various different factors that can affect the range side lobe levels and examined their effect either experimentally or through simulations. The technique has the potential for improving signal-to-noise ratio (SNR), maximum penetration depth and resolution without exceeding peak intensity limitations. Some possible applications are discussed that merit further evaluation. Our work demonstrates the feasibility of this technique and presents a theoretical framework that can be used in future studies aimed at evaluating image quality, system performance, and possible artifacts under such an imaging scheme.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical use and evaluation of coded excitation in B-mode images

Use of long encoded waveforms can be advantageous in ultra-sound imaging, as long as the pulse compression mechanism ensures low range sidelobes and preserves both axial resolution and contrast. A coded excitation/compression scheme was previously presented by our group, which is based on a predistorted FM excitation and a mismatched compression filter designed for medical ultrasonic applicatio...

متن کامل

Analysis and Spectral Characteristics of a Spread-Spectrum Technique for Conducted EMI Suppression

Frequency modulation (FM) and random switching methods have been used for reducing conducted electromagnetic interference (EMI) in power converters. Limited theoretical studies and comparisons of these schemes, however, are available. In this paper, a detailed analysis and the spectral characteristics of a random carrier-frequency (RCF) technique for suppressing conducted EMI in an offline swit...

متن کامل

Multispectral ultrasound imaging and analysis of speckle generating medium

Navalgund Rao. Member, IEEE and Mark Aubry* Center for Imaging Science, Rochester Institute of Technology Rochester, NY 14623 The potential of a pulse compression technique has been experimentally evaluated for speckle reduction processing. Multifrequency and multibandwidth data were obtained from a speckle generating medium using frequency modulated pulses. Speckle decorrelation factors were c...

متن کامل

Evaluation of the Effect of Tumor Position on Standardized Uptake Value Using Time-of-Flight Reconstruction and Point Spread Function

Objective(s): The present study was conducted to examine whether the standardized uptake value (SUV) may be affected by the spatial position of a lesion in the radial direction on positron emission tomography (PET) images, obtained via two methods based on time-of-flight (TOF) reconstruction and point spread function (PSF). Methods: A cylinder phantom with the sphere (30mm diameter), located in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasonic imaging

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 1995