Methodology and reporting of diagnostic accuracy studies of automated perimetry in glaucoma: evaluation using a standardised approach.

نویسندگان

  • Bruno M R Fidalgo
  • David P Crabb
  • John G Lawrenson
چکیده

PURPOSE To evaluate methodological and reporting quality of diagnostic accuracy studies of perimetry in glaucoma and to determine whether there had been any improvement since the publication of the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines. METHODS A systematic review of English language articles published between 1993 and 2013 reporting the diagnostic accuracy of perimetry in glaucoma. Articles were appraised for methodological quality using the 14-item Quality assessment tool for diagnostic accuracy studies (QUADAS) and evaluated for quality of reporting by applying the STARD checklist. RESULTS Fifty-eight articles were appraised. Overall methodological quality of these studies was moderate with a median number of QUADAS items rated as 'yes' equal to nine (out of a maximum of 14) (IQR 7-10). The studies were often poorly reported; median score of STARD items fully reported was 11 out of 25 (IQR 10-14). A comparison of the studies published in 10-year periods before and after the publication of the STARD checklist in 2003 found quality of reporting had not substantially improved. CONCLUSIONS Methodological and reporting quality of diagnostic accuracy studies of perimetry is sub-optimal and appears not to have improved substantially following the development of the STARD reporting guidance. This observation is consistent with previous studies in ophthalmology and in other medical specialities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated achromatic perimetry

Visual field (VF) testing is an important diagnostic tool for Glaucoma. The current gold standard for VF testing is automated perimetry. This article is an attempt to familiarize the reader with components of an achromatic (white on white) automated perimetry printout. It addresses use of Humphrey perimeter to interpret the results. For the purpose of this review, a PubMed search was made using...

متن کامل

Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy

Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...

متن کامل

A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma.

PURPOSE To describe an approach for the evaluation of covariate effects on receiver operating characteristic (ROC) curves and to apply this methodology to the investigation of the effects of disease severity and age on the diagnostic performance of frequency doubling technology (FDT) and standard automated perimetry (SAP) visual function tests for glaucoma detection. METHODS The study include...

متن کامل

The quality of reporting of diagnostic accuracy studies in glaucoma using the Heidelberg retina tomograph.

PURPOSE Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS A validated Medline and hand search of English-language articles reporting on measu...

متن کامل

A comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.

Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2015