Contamination of patient blood samples by avian RBCs from control material during automated hematology analysis.

نویسندگان

  • Lisa Senzel
  • Bruce Kube
  • Mabel Lou
  • Alice Gibbs
  • Tahmeena Ahmed
  • Brent Hall
چکیده

OBJECTIVES Atypical nucleated RBCs (NRBCs) found on several patient blood smears between 2010 and 2012 were noted to resemble avian RBCs. NRBCs are not normally found in the circulation beyond the neonatal period and may indicate hematologic disease, malignancy in the bone marrow, or other severe conditions. Our blood smears with unusual NRBCs did not contain other abnormalities that typically accompany NRBCs, such as immature cells or dysplastic granulocytes. To investigate this anomaly, we considered possibilities such as contaminated collection tubes and instrument problems. The Retic-C Cell Control used with the LH 750 Hematology Analyzer contains a mixture of human and avian RBCs. METHODS CBC count with differential tests were performed on blanks and routine laboratory samples run immediately after the Retic-C Cell Control on the LH 750 and LH 780 analyzers to recreate the conditions that might cause spillage into the next tube. RESULTS We experimentally reproduced the phenomenon of contamination of a subsequent tube with avian cells from a multiply punctured reticulocyte control tube. CONCLUSIONS We concluded that the NRBCs likely represented avian RBCs from the Retic-C Cell Control that had been introduced into the patient tubes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تفسیر هیستوگرام‏های اریتروسیتی به‌دست‌آمده از دستگاه‏های خودکار هماتولوژی در بیماری‏های خونی معمول

Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams) that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC). To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use thos...

متن کامل

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

Comparison of Delta- PCR and Conventional Fragment Analysis for the Detection of FLT3-ITD Mutations in Paired Diagnosis-Relapse Samples of Patients with Acute Myeloid Leukemia

Background & Objective: FLT3-ITD mutation detection has been an integral part of diagnostic work ups focused on acute myeloid leukemia. However, some studies have indicated that the mutation is unstable during the various stages of the disease. The purpose of this study was to evaluate the stability of this marker in paired diagnosis-relapse samples using Delta-PCR method. Materials & Methods:...

متن کامل

Automated quantitation of fetomaternal hemorrhage by flow cytometry for HbF-containing fetal red blood cells using probability state modeling.

BACKGROUND Flow cytometric methods (FCMs) are the contemporary standard for fetal red blood cell (RBC) quantitation and fetomaternal hemorrhage (FMH) detection. FCM provides greater sensitivity and repeatability relative to manual microscopic Kleihauer-Betke methods. FCM assays are not totally objective, employing subjective manual gating of fetal RBCs with measureable interobserver imprecision...

متن کامل

Bacterial Contamination and Antibiotic Resistance of Staphylococcus Aureus Isolated from Automated Teller Machine

Abstract Background and Objective: Automated Teller Machine (ATMs) is likely to be contaminated with various microorganisms specially pathogen germs. This may be due to their exposure to dust and their vast dermal contact with multiple users. This study investigated the bacterial contamination on the keyboard of ATMs and drug resistance of the bacteria isolated from them. Material and M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 140 1  شماره 

صفحات  -

تاریخ انتشار 2013