A Novel Protection Method for Single Line-to-Ground Faults in Ungrounded Low-Inertia Microgrids
نویسندگان
چکیده
Abstract: This paper proposes a novel protection method for single line-to-ground (SLG) faults in ungrounded low-inertia microgrids. The proposed method includes microgrid interface protection and unit protection. The microgrid interface protection is based on the difference between the zero-sequence voltage angle and the zero-sequence current angle at the microgrid interconnection transformer for fast selection of the faulty feeder. The microgrid unit protection is based on a comparison of the three zero-sequence current phase directions at each junction point of load or distributed energy resources. Methods are also included to locate the minimum fault section. The fault section location technology operates according to the coordination of microgrid unit protection. The proposed method responds to SLG faults that may occur in both the grid and the microgrid. Simulations of an ungrounded low-inertia microgrid with a relay model were carried out using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including DC (EMTDC).
منابع مشابه
Applying Frequency Response method for contact Rails Fault Diagnosing in Ungrounded Electrical Railway System
Abstract General faults in regular electrical railways system could be detect by implementing the specific protection functions such as ground fault or sensitive earth fault. Otherwise, in ungrounded electrical railway systems which using both feeding and return contact rail at the same time, fault detection cannot done with above-mentioned function. Due to recent growth in electrical railway ...
متن کاملUnsynchronized Phasor-Based Protection Method for Single Line-to-Ground Faults in an Ungrounded Offshore Wind Farm with Fully-Rated Converters-Based Wind Turbines
This paper proposes a protection method for single line-to-ground (SLG) faults in an ungrounded offshore wind farm with fully-rated converter-based wind turbines. The proposed method uses the unsynchronized current phasors measured by unit protections installed at the connection point of the fully-rated converter (FRC)-based wind turbines (WTs). Each unit protection collects the unsynchronized ...
متن کاملAn Intelligent Protection Method for Multi-terminal DC Microgrids Using On-line Phaselet, Mathematical Morphology, and Fuzzy Inference Systems
In this paper, a new method for fault detection, location, and classification in multi-terminal DC microgrid (MTDC) is proposed. MTDC grids have expanded due to some issues such as the expansion of DC resources, loads, and aims to increase power quality. Diagnosing the types and location of faults is important to continue the service and prevent further outages. In this method, a circuit kit is...
متن کاملA Novel Ground Fault Non-Directional Selective Protection Method for Ungrounded Distribution Networks
This paper presents a new selective and non-directional protection method to detect ground faults in neutral isolated power systems. The new proposed method is based on the comparison of the rms value of the residual current of all the lines connected to a bus, and it is able to determine the line with ground defect. Additionally, this method can be used for the protection of secondary substati...
متن کاملWavelet based Fault Detection Method for Ungrounded Power System with Balanced and Unbalanced load
Modern spectral and harmonic analysis is based on Fourier transforms. However, these techniques are less efficient in tracking the signal dynamics for transient disturbances. Consequently, the wavelet transform has been introduced as an adaptable technique for non-stationary signal analysis. Although the application of wavelets in the area of power system engineering is still relatively new, it...