Clinical significance of central corneal thickness in the management of glaucoma.

نویسندگان

  • Carolyn Y Shih
  • Joshua S Graff Zivin
  • Stephen L Trokel
  • James C Tsai
چکیده

OBJECTIVE To evaluate the effect of central corneal thickness determination on the clinical management of patients with glaucoma and glaucoma suspect. METHODS A cross-sectional retrospective study was performed on 188 consecutive patients. Mean ultrasound pachymetry measurements of central corneal thickness and corresponding Goldmann applanation tonometry measurements were obtained. Intraocular pressures (IOPs) were corrected using linear and mathematical (Orssengo-Pye) algorithms. Measurement-significant outcomes were defined as an IOP adjustment of 1.5 mm Hg or greater and outcomes-significant results as an IOP adjustment of 3.0 mm Hg or greater. Changes in therapy such as the use of eyedrops and addition or cancellation of laser therapy or surgery were then noted for those individuals with measurement- or outcomes-significant changes. RESULTS Using the linear correction scale, 105 (55.9%) of 188 patients had at least a measurement-significant adjustment in their IOP measurements: 67 (35.6%) had adjustments between 1.5 and 3.0 mm Hg, while 38 (20.2%) had an outcomes-significant IOP adjustment (> or =3.0 mm Hg). Among the 188 patients, 16 (8.5%) had a change in eyedrop therapy, 4 (2.1%) had a change regarding laser therapy, and 6 (3.2%) had a change in the decision regarding glaucoma surgery. Using the exponential correction (Orssengo-Pye) scale, similar percentages were obtained. CONCLUSION Pachymetry-measured central corneal thickness has a significant effect on the clinical management of patients with glaucoma and glaucoma suspect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Comparative biometric study between plateau iris configuration and primary open angle glaucoma with narrow angle.

PURPOSE To investigate biometrically the differences between plateau iris configuration (PIC) eyes and primary open angle glaucoma with narrow angle eyes. METHODS A comparative study involving a case series with 20 eyes of 11 plateau iris configuration patients and 45 eyes of 27 primary open angle glaucoma with narrow angle eyes patients was done. The following measurements were taken: cornea...

متن کامل

The importance of central corneal thickness measurements and decision making in general ophthalmology clinics: a masked observational study

BACKGROUND To assess the impact of knowing central corneal thickness (CCT) on glaucoma management in a United Kingdom district general hospital. METHODS A masked observational non-interventional study included 304 eyes of 152 consecutive glaucoma cases attending general clinic. CCT was measured using a hand-held pachymeter. IOP, as measured by the Goldmann applanation tonometer (GAT), was adj...

متن کامل

Longitudinal effect of topical antiglaucoma medications on central corneal thickness.

BACKGROUND To determine the change in central corneal thickness over time and whether the use of long-term topical antiglaucoma medications influences central corneal thickness. DESIGN Case control study with retrospective and prospective data collection. PARTICIPANTS One hundred eighty-seven eyes of 187 glaucoma patients (mean follow up 6.92 ± 1.67 years) being treated with topical antigla...

متن کامل

Central corneal thickness as a risk factor for advanced glaucoma damage.

OBJECTIVE To determine if central corneal thickness (CCT) is related to the level of glaucoma severity at the initial examination. METHODS The initial visit to a glaucoma specialist by consecutive patients with primary open-angle glaucoma from 1997 to 2002 was reviewed retrospectively. Each patient's age, sex, race, family history of glaucoma, number of glaucoma medications, visual acuity, sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 122 9  شماره 

صفحات  -

تاریخ انتشار 2004