Highly sensitive phage-based biosensor for the detection of -galactosidase

نویسندگان

  • Viswaprakash Nanduri
  • Shankar Balasubramanian
  • Srinivas Sista
  • Vitaly J. Vodyanoy
  • Aleksandr L. Simonian
چکیده

Development of real-time sensor based on the target-specific probe that make possible sensitive, rapid and selective detection and monitoring of the particular antigen molecules could be of substantial importance to the many applications. Because of its high specificity to the target molecules, excellent temperature stability, and easy production, bacterial phage might serve as a powerful biorecognition probe in biosensor applications. Here, we report extremely sensitive and specific label-free direct detection of model antigen, -galactosidase ( -gal), based on surface plasmon resonance (SPR) spectroscopy. The -gal specific landscape phage 1G40 has been immobilized on the gold surface of SPR SPREETATM sensor chip through physical adsorption [V. Nanduri, A.M. Samoylova, V.Petrenko, V. Vodyanoy and A.L.Simonian, Comparison of optical and acoustic wave phage biosensors, 206th Meeting of The Electrochemical Society, Honolulu, Hawaii, October 3–8, (2004)]. Another non-specific to the -gal phage, a wild-type phage F8-5, was used in the reference channel. The concentration-dependent binding of -gal in both channels were assessed by monitoring the sensor optical response as a function of time under different experimental conditions, and the concentration of -gal was computed in differential mode. Concentrations of -gal between 10−12 M and 10−7 M could be readily detected, with linear part of calibration curve between 10−9 M and 10−6 M. When -gal was pre-incubated with different concentrations of free 1G40 phage prior to exposure to the biosensor, concentration-dependent inhibition was observed, indicating on biosensor high specificity toward -gal. Apart from a flow through mode used to deliver the samples to the surface for the SPR sensor, batch mode sensing was also employed to study the binding of -gal to immobilized phage on the SPR sensor surface. Experiments using a flow through mode provided more consistent results in the full dose range and showed higher sensitivity as opposed to the batch mode studies. The mean Kd and binding valences for the flow through mode studies was 1.3± 0.001 nM and 1.5± 0.03, in comparison to 26± 0.003 nM and 2.4± 0.01 for the batch mode studies. The average thickness of phage 1G40 adlayer deposited through flow through and batch mode was 3± 0.002 and 0.66± 0.001 nm, respectively. © 2007 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Sensitive Novel Approach towards the Detection of 8-Hydroxyquinoline at Anionic Surfactant Modified Carbon Nanotube Based Biosensor: A Voltammetric Study

A rapid electrochemical technique was developed to determine 8-Hydroxyquinoline (8HQ). In the current study, the anionic surfactant Sodium lauryl sulfate (SLS) was immobilized on the multi-walled carbon nanotube (MWCNT) paste surface for the fabrication of electrode to detect 8HQ in phosphate buffer solution (PBS) of pH 7.0. The response of SLS modified carbon nanotube paste electrode (SLSMCNTP...

متن کامل

Ultra-Sensitive Optical Biosensor Based on Whispering Gallery Modes: The Effect of Buffer Solutions Refractive Index on Their Sensitivity and Performance

Background: Whispering gallery modes (WGM) biosensors are ultrasensitive systems that can measure amount of adsorbed layer onto the micro-cavity surface. They have many applications including protein, peptide growth, DNA and bacteria detection, molecular properties measurements and specific interaction and drug table recognitions due to their high sensitivity, compact size and label free sensin...

متن کامل

Micro-cantilevered MEMS Biosensor for Detection of Malaria Protozoan Parasites

In this paper, the presented work aims to provide a designed model based on Finite element method for detection of Malaria protozoan parasites. Micro-cantilevers are next generation highly efficient biosensors for detection and prevention of any disease. Here, an E-shaped model for micro cantilevered biosensor is designed using COMSOL Multiphysics specifically for detection of Malaria. Microcan...

متن کامل

غنی‌سازی کتابخانه ژنی نانوبادی علیه پروتئین سطحی ویروس پاپیلومای انسانی عامل سرطان دهانه رحم

Background and Objective: The human papillomavirus (HPV) is the main cause of cervical cancer. The symptoms of the disease are non-specific and it can be transferred from one person to another one. In order to prevent the spread of HPV virus and reducing mortality rate of cervical cancer, early detection programs are needed. Accurate and highly sensitive test is essential for screening examinat...

متن کامل

Au nanorods/ g-C3N4 composite based biosensor for electrochemical detection of chronic lymphocytic leukemia

Objective: With the increasing incidence of cancer and the dramatic effect of early detection on treatment and increase patient's life, many efforts have been devoted to making sensitive diagnosis systems. DNA as a biomarker for diagnosis of different types of cancers at the early stages of illness has attracted much attention.Methods: In this research novel electrochemical biosensor was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007